Eight-Door Concentrator

2305 Bering Drive

01959-001 Rev. 1.1

San Jose, CA  95131   USA
(800) 260-5265  (408) 435-8400  FAX (408) 577-1792
Web: http://www.kerisys.com  E-mail: [email protected]

Page 22 of 24

Quick S

tart Guide

KDC-8

4.1

B-Reader Jumper Cables

Four sets are provided with the concentrator. These cables connect the individual controller B-
Reader connections to the concentrator. This wiring diagram is provided should a reader jumper 
cable be lost.

Figure 28: B-Reader Jumper Cable Wiring

4.2

TB10 Relay Output Jumper Cables

Four sets are provided with the concentrator. These cables connect the individual controller TB10 
connections to the concentrator. This wiring diagram is provided should a TB10 jumper cable be 
lost.

Figure 29: TB10 Jumper Cable Wiring

Содержание KDC-8

Страница 1: ...ications Height 15 inches plus 0 25 inches for the cover Width 17 inches plus 0 25 inches for the cover Depth 6 5 inches plus 0 25 inches for the cover Weight 19 pounds including controllers and satel...

Страница 2: ...screw slots and three screw through holes for secure mounting Have an assistant hold the unit in the desired mounting place and mark the mounting locations see Figure 2 if there are controllers in the...

Страница 3: ...ail sales kerisys com Page 3 of 24 KDC 8 Quick Start Guide 2 2 Bracket Wall Mounting Attach the brackets to the rear of the cabinet sides see Figure 3 Have an assistant hold the unit in the desired mo...

Страница 4: ...Have an assistant hold the unit in the desired mounting place and mark the mounting locations see Figure 4 Drill pilot holes in the marked locations and then install the unit Note When fully loaded th...

Страница 5: ...www kerisys com E mail sales kerisys com Page 5 of 24 KDC 8 Quick Start Guide 2 3 Rack Mounting The cabinet is designed to be installed in a standard IT Server Telecom rack using the two rack mount br...

Страница 6: ...com Page 6 of 24 Quick Start Guide KDC 8 Have an assistant hold the cabinet in the desired mounting place on the rack and secure the cabinet using the rack mount screws see Figure 6 and Figure 7 a ge...

Страница 7: ...cks The unit can use one power supply to drive both the controllers and the lock relays or have separate power supplies one for the controllers and one for the door lock relays Each door lock relay ca...

Страница 8: ...5 Bering Drive 01959 001 Rev 1 1 San Jose CA 95131 USA 800 260 5265 408 435 8400 FAX 408 577 1792 Web http www kerisys com E mail sales kerisys com Page 8 of 24 Quick Start Guide KDC 8 Figure 8 Extern...

Страница 9: ...is the left LED on the face of the cabinet see Figure 1 on page 1 Should the cable come free connect the cable to J28 pins 1 and 2 with the RED wire connected to pin 1 Refer to Figure 9 3 3 Cabinet Co...

Страница 10: ...8 3 4 Individual Controller Wiring Connections Around the perimeter of the PCB is a ring of 32 connectors Each connector on the four controllers satellite boards has a corresponding connector on the...

Страница 11: ...5 and TB6 Controllers will either be Keri Proximity PXL 500P see Figure 11 or Wiegand PXL 500W Figure 12 Make the wiring connections from the Reader to the appropriate connector accordingly A Reader t...

Страница 12: ...2 A Door Lock Relay Alarm Relay Outputs TB3 Make the wiring connections for the A Door Lock and Alarm Relays TB3 Use Figure 10 on page 10 to locate the correct connectors for each controller For the...

Страница 13: ...ock Alarm Relay usage or for general purpose outputs TB7 Use Figure 10 on page 10 to locate the correct connectors for each controller For the Lock Relay power is applied to the common line This provi...

Страница 14: ...es depending upon the configuration of the controller s satellite board as the A and B Door Held Open Outputs OR as general purpose outputs 3 and 4 Make the wiring connections for either Door Held Ope...

Страница 15: ...for each controller On the master controller the final input on TB4 can serve one of two purposes It can either act as an Auxiliary Request to Exit for the A Door or as a Global Unlock for the access...

Страница 16: ...tus Switch Request to Exit Auxiliary Request to Exit General Purpose Input 4 TB8 Make the wiring connections for the B Door Status Switch Request to Exit and Auxiliary Request to Exit inputs TB8 Make...

Страница 17: ...Web http www kerisys com E mail sales kerisys com Page 17 of 24 KDC 8 Quick Start Guide 3 4 7 General Purpose Inputs 5 6 7 8 TB9 Make the general purpose input 5 6 7 and 8 connections if required TB9...

Страница 18: ...s com E mail sales kerisys com Page 18 of 24 Quick Start Guide KDC 8 3 5 RS 485 Network J1 and J8 allow you to daisy chain the RS 485 access control network see Figure 21 Connect the incoming RS 485 l...

Страница 19: ...he power supply to J43 see Figure 24 Power can be from an independent power supply or can be daisy chained from the controller cabinet power supply Section 3 7 on page 20 Power is provided to the rela...

Страница 20: ...7 1792 Web http www kerisys com E mail sales kerisys com Page 20 of 24 Quick Start Guide KDC 8 3 7 Cabinet Power J21 provides power to the controllers see Figure 25 Connect the line from the controlle...

Страница 21: ...into the backplane carefully align the connectors on the controller with the plugs on the backplane and slide the controller into place It will be a firm snug connection Once all four controllers are...

Страница 22: ...ncentrator These cables connect the individual controller B Reader connections to the concentrator This wiring diagram is provided should a reader jumper cable be lost Figure 28 B Reader Jumper Cable...

Страница 23: ...controller is a power switch and a power ON LED This provides maximum flexibility in powering up the unit and in swapping boards When ready simply switch ON each controller one at a time and verify po...

Страница 24: ...DC 8 5 2 Closing the Cabinet The Concentrator cabinet cover has a slip hinge that allows you to completely remove the cover when working inside the unit It has a single lock that provides cabinet secu...

Отзывы: