2
KFD 62528W/060801
5.0 OUTPUT SPECIFICATIONS (SEE TABLES 2, 3, AND 4)
TABLE 2. OUTPUT SPECIFICATIONS FOR THE KFD UNIT
Parameter
Description
Output Voltage Nominal
5V
Output Current Nominal
30A
Output Power Maximum
150W
Ripple
1
50mV RMS max.
Noise, 5Hz to 20Mhz
100 mV p-p max.
Output Current Minimum
1.0A
Output Current Maximum
30.0A
1
At less than minimum load the DC to DC converter may exceed its output ripple specification
TABLE 3. DYNAMIC RESPONSE FOR THE KFD UNIT
Characteristic
Specification
Dynamic Response to Load
Change
V
I
=48 Volts, T
A
=25°C
From Io = 50% to 75% I
o,max
and from Io=50% to 25% I
o,max.
Typical
Unit
Peak Deviation
150
mV
Settling Time (V
o
< 10% of
Peak Deviation)
300
µ
S
∆
Io
∆
T
----------
1
A
10
µ
S
--------------
=
Содержание KFD 6-25-28W
Страница 2: ......
Страница 17: ...KFD 6 25 28 060801 13 FIGURE 3 MECHANICAL OUTLINE DRAWING OF THE SINGLE OUT PUT KFD DC TO DC CONVERTER...
Страница 18: ...14 KFD 62528W 060801 FIGURE 4 REMOTE ON OFF WIRING CONFIGURATION FOR THE SINGLE OUTPUT KFD DC TO DC CONVERTER...
Страница 20: ...16 KFD 62528W 060801 FIGURE 6 CIRCUIT CONFIGURATION FOR SINGLE KFD DC TO DC CONVERTER REMOTE SENSE OPERATION...
Страница 22: ...18 KFD 62528W 060801 FIGURE 9 HEAT SINKS FOR VERTICAL ORIENTATION KEPCO MODEL KFD 02 AND THE KEPCO MODEL KFD 04...
Страница 25: ...KFD 6 25 28 060801 21 FIGURE 12 HEAT SINK DERATING CURVES NATURAL CONVECTION FINS ORIENTED ALONG THE WIDTH...
Страница 26: ...22 KFD 62528W 060801 FIGURE 13 HEAT SINK DERATING CURVES NATURAL CONVECTION FINS ORIENTED ALONG THE LENGTH...
Страница 28: ......