background image

HSF 300W 042315

1

1.

INTRODUCTION

1.1

SCOPE OF MANUAL

This Operator's Manual covers the installation and operation of the Kepco HSF 300W Series of
Switching Power Supplies. For service information, write directly to: Kepco Inc., 131-38 Sanford
Avenue, Flushing, New York, 11355, U.S.A. Please state Model Designation and Serial Number of
your HSF Power Supply. This information can be found on the nameplate of the unit. 

1.2

DESCRIPTION

The Kepco HSF 300 Watt Series are hot swappable, high frequency switching, plug-in power sup-
plies that are completely interchangeable with the metered HSF Series. Six models may be
selected for outputs of 5V, 12V, 15V, 24V, 28V or 48V. They employ forward conversion and power
factor correction and are designed to operate in a fault tolerant power system with a nominal a-c
input of 100V a-c to 240V a-c (input voltage range 85 to 265 Va-c), 50-60 Hz (input frequency
range 47-440Hz). A built-in current balancing circuit and OR-ing diodes allow configuration for
hot-swap and parallel-redundant N+1 operation.

These power supplies are designed to be used with Kepco's Series RA 19-4C rack adapters. The
RA 19-4C rack adapter accepts up to four 300W modules. All input/output connections are
through a 24-pin connector that plugs in to the rack adapter. All external connections described in
the following paragraphs are made through the rack adapter’s I/O connector (see Figure 1). 

FIGURE 1.  HSF REAR PANEL CONNECTOR AND RA 19-4C RACK ADAPTER I/O CONNECTOR

TABLE 1.  HSF REAR CONNECTOR PIN ASSIGNMENTS

Signal 

Name

Pin

Function

1, 2, 4

DC output (+) applied to load.

Output –

3, 5, 6

DC Output (–) applied to load.

SENSE–

7

Sense– connection

IMON+

8

Current  (sense resistor).

SENSE+

9

Sense+ connection

NO

10

Normally Open contact of alarm relay, referenced to AL COM, pin 14 (see PAR. 3.7.2.1).

IMON–

11

Current Monitor– (sense resistor).

–COM

12

–Signal Common provides return for REF, pin 15, and RV, pin 18, signals.

NC

13

Normally Closed contact of alarm relay, referenced to AL COM, pin 14 (see PAR. 3.7.2.1).

AL COM

14

Common contact of alarm relay (see PAR. 3.7.2.1).

REF

15

Reference voltage. When used with RV, pin 18, allows all output voltages of paralleled slave supplies to be 
controlled by one voltage adjustment of a master power supply. When REF is connected to RV via an 
external trimmer, the external trimmer determines output voltage (see PAR. 3.4.2). Connections are made 
via DIP switches (see PAR. 3.1).

3042951

8

9

7

12 11 10

15

18

16

17

14 13

21 20 19

2

1

3

4

5

6

22

23

24

Содержание HSF 12-27

Страница 1: ...he correct revision for your particular model and serial number 3 The contents of this manual are protected by copyright Reproduction of any part can be made only with the specific written permission...

Страница 2: ...Power Options 11 3 9 Local remote Sensing 12 3 10 Retaining Latches 12 4 Load Connection 12 5 Connecting Multiple Power Supplies 12 1 HSF Rear Panel Connector and RA 19 4C Rack Adapter I O Connector 1...

Страница 3: ...ack adapter accepts up to four 300W modules All input output connections are through a 24 pin connector that plugs in to the rack adapter All external connections described in the following paragraphs...

Страница 4: ...Amps 4 63 78 28 4 35 1 23 1 28 6 14 7 18 2 12 6 15 6 7 4 9 1 Short Circuit Current Amps 82 35 29 20 17 11 Overvoltage Protection OVP Volts d c 5 5 7 7 0 14 3 16 8 18 0 24 0 29 3 33 6 34 2 39 2 54 5 59...

Страница 5: ...nt flow into EMI filter 15A typ 20A max first surge 100 120V ac 30A typ 40 max first surge 200 240 V ac Leakage Current 0 24mA typ 0 3mA max 120V a c 60Hz per IEC 950 and UL1950 0 31mA typ 0 38mA max...

Страница 6: ...f 3 axes sweep time 10 minutes Shock Acceleration 643 5ft s2 196 1M s2 20g Pulse Duration 11ms 5 msec non operating 1 2 sine pulse three shocks on each axis Power Supply is fixed on its bottom side Sa...

Страница 7: ...front panel reset button to be used to reset the unit after a fault or allow Remote on off via mechanical switch or logic level see PAR 3 5 Positions 5 and 6 allows alarm signals to be produced from e...

Страница 8: ...er in the event that overcurrent or overvoltage protection has tripped or thermal overload or fan mal function has occurred If remote voltage control see PAR 3 4 2 is not enabled the front panel Vadj...

Страница 9: ...ONTROL Output voltage can be manually adjusted with the voltage adjustment control Vadj see Figure 5 for location when DIP switches SW1 and SW2 see Figure 4 for location are configured as shown in Fig...

Страница 10: ...the output may be turned ON or OFF using the RC signals if the remote ON OFF feature is enabled Note that when remote ON OFF is enabled the RESET OUTPUT switch does not function Remote ON OFF is enabl...

Страница 11: ...beyond allowable limit the output is cut OFF and the fans turn OFF The restart cycle Power ON should not begin until the temperature returns to within specifications To restart reset the unit set the...

Страница 12: ...imums per Table 4 if enabled see PAR 3 8 3 7 2 ALARM SIGNALS Either of two options are available for signalling alarms isolated relay contacts factory default PAR 3 7 2 1 or logic level alarm signals...

Страница 13: ...IRCUIT OPTICALLY ISOLATED FIGURE 11 PF POWER FAILURE OPTOCOUPLER TIMING DIAGRAM 3 8 VDC ON ALARM INDICATOR POWER OPTIONS To use the internal power supply reference voltage to power the VDC ON ALARM in...

Страница 14: ...POWER SUPPLIES All connections to multiple HSF power supplies must be made via the I O mating connectors at rear of the Rack Adapter or by the Rack Adapter DIP switches These connections including th...

Отзывы: