EMI:  

Designed to meet FCC Class B (100-120V a-c) and VDE 0871

Class B (220-240V a-c).

VIBRATION:  

(non-operating, one hour on each one of the three

axes):

5-10 Hz, 10 mm amplitude.

10-55 Hz, 2g acceleration.

SHOCK:  

(non-operating, one-half sinusoidal pulse, three shocks to

each axis):

Acceleration: 20g 

Duration: 11ms +5ms

OPERATING TEMPERATURE:  

See Figure 4.

STORAGE TEMPERATURE:  

-40

o

C to +75

o

C.

OPERATING AND STORAGE RELATIVE HUMIDITY:  

up to 95%

(wet bulb temp. <35

o

C non-condensing).

FUSE:  

Quick acting 6.3A, 250V; (5.2 x 20mm), San-O P/N EQ6.3A;

Kepco P/N 541-0113

.

DIMENSIONS: See Figure 5.

WARRANTY:

 5 years.

FIGURE 4.  % OUTPUT POWER RATING VS. 

AMBIENT TEMPERATURE

FIGURE 5.  HSF POWER SUPPLY OUTLINE DRAWING

Содержание HSF 12-12

Страница 1: ... OFF switch must be set to OFF before removing unit from rack adapter The front panel MASTER ON LED lights when 1 the unit operates independently or 2 the unit is used in parallel redundant configurations while a the output is less than 10 of nominal or b the output is within 10 to 100 of nominal and the unit is functioning as a master In parallel redundant configurations the module with the highe...

Страница 2: ...it Current nominal output at rated load 120V a c rms 3 0A a c typ 3 5A a c max 240V a c rms 1 5A a c typ 2 0A a c max Initial Turn on Surge one half of first input cycle 120V a c rms 25A max 240V a c rms 50A max When the a c input power is removed the inrush current limit circuit requires 30 seconds recovery time before the a c input power is reconnected Brownout Voltage 85V a c 110V d c Switching...

Страница 3: ...t to the load goes below 10 for each unit in current share mode all MASTER ON lights may go on see load effect specifications this indicates that forced cur rent share is no longer working units are simply in current share mode If forced current sharing at less than 10 nominal current per supply is needed contact Kepco application engineering Remote sensing is recommended For master slave operatio...

Страница 4: ...z 10 mm amplitude 10 55 Hz 2g acceleration SHOCK non operating one half sinusoidal pulse three shocks to each axis Acceleration 20g Duration 11ms 5ms OPERATING TEMPERATURE See Figure 4 STORAGE TEMPERATURE 40o C to 75o C OPERATING AND STORAGE RELATIVE HUMIDITY up to 95 wet bulb temp 35o C non condensing FUSE Quick acting 6 3A 250V 5 2 x 20mm San O P N EQ6 3A Kepco P N 541 0113 DIMENSIONS See Figure...

Отзывы: