SAFETY:  

UL60950 3rd Edition and CSA 22.2 No. 60950.  Units designed to meet EN 60950 and are CE marked per the Low

Voltage Directive (LVD), 73/23/EEC and 93/68/EEC. [The standards do not apply with DC input operation.]

I/O CONNECTOR:  

The 24-pin I/O connector (Figure 2) is designed to mate with the corresponding connector in the Series

RA 19-(X)B Rack Adapter.

#

 

(+) SENSE, (–) SENSE: 

 These lines are provided to compensate for voltage drops in the load connecting wires. The

Sense lines must be connected to their respective (+) and (–) output terminals, either at the load or at the rack adapter

(see Rack Adapter Manual). The connection ensures the most accurate error tracking. Error compensation in the connect-

ing wires is up to 0.25 Volts per lead for all models.

NOTE:

The Sense lines must be connected for the HSF Power supply to work properly!

#

OUTPUT (+), OUTPUT (–): 

 HSF power supply d-c output.

#

CURRENT SHARE BUS (CSB): 

Connecting the CSB lines of HSF power supplies operating in a parallel configuration

causes output current to be shared equally. (See Rack Adapter Manual for additional information on parallel configura-

tions.). For current sharing to work properly the outputs of all paralleled units must be within 250 mV (max) of each other

and each unit must be operating at between 10% to 100% of rated output. If current to the load goes below 10% for each

unit in current share mode, all MASTER ON lights may go on (see load effect specifications); this indicates that forced cur-

rent share is no longer working, units are simply in current share mode. (If forced current sharing at less than 10% nominal

current per supply is needed, contact Kepco application engineering.) Remote sensing is recommended. For master/slave

operation to work properly each unit should be adjusted to 40 mV (optimum) less than the next paralleled unit (unit 1 is

adjusted to V

OUT

, unit 2 to V

OUT

 – 40mV, and unit 3 to V

OUT

 – 80mV, etc. If the master fails, the unit 2 will become the new

master). The 40 mV difference can be reduced to a minimum of 25 mV as needed to parallel many units and still keep all

units within 250 mV of each other. Adjust the outputs using Vadj trimmer on front panel. 

• Optimum difference among output voltages of paralleled units: 40mV
• Maximum difference among output voltages of paralleled units: 250 mV
• Minimum difference among output voltages of paralleled units: 25 mV

#

ALARM: 

 The Alarm NC (normally closed) - Open on Failure and Alarm NO (normally open) - Close on Failure lines are

relay contacts referenced to Alarm Common. If the unit fails, the path between Alarm NC - Open on Failure and Alarm

Common opens, the path between Alarm NO - Close on Fail and Alarm Common is a short circuit. Figure 3 illustrates typ-

ical Close on Fail and Open on Fail circuits to give a failure indication if any one of a number of power supplies fail.

#

INPUT POWER: 

Line (either a-c or d-c source power), Neutral and Ground (chassis)

FIGURE 3.  TYPICAL ALARM CIRCUIT DIAGRAMS

FIGURE 2.  REAR CONNECTOR PIN ASSIGNMENTS

Содержание HSF 12-12

Страница 1: ... OFF switch must be set to OFF before removing unit from rack adapter The front panel MASTER ON LED lights when 1 the unit operates independently or 2 the unit is used in parallel redundant configurations while a the output is less than 10 of nominal or b the output is within 10 to 100 of nominal and the unit is functioning as a master In parallel redundant configurations the module with the highe...

Страница 2: ...it Current nominal output at rated load 120V a c rms 3 0A a c typ 3 5A a c max 240V a c rms 1 5A a c typ 2 0A a c max Initial Turn on Surge one half of first input cycle 120V a c rms 25A max 240V a c rms 50A max When the a c input power is removed the inrush current limit circuit requires 30 seconds recovery time before the a c input power is reconnected Brownout Voltage 85V a c 110V d c Switching...

Страница 3: ...t to the load goes below 10 for each unit in current share mode all MASTER ON lights may go on see load effect specifications this indicates that forced cur rent share is no longer working units are simply in current share mode If forced current sharing at less than 10 nominal current per supply is needed contact Kepco application engineering Remote sensing is recommended For master slave operatio...

Страница 4: ...z 10 mm amplitude 10 55 Hz 2g acceleration SHOCK non operating one half sinusoidal pulse three shocks to each axis Acceleration 20g Duration 11ms 5ms OPERATING TEMPERATURE See Figure 4 STORAGE TEMPERATURE 40o C to 75o C OPERATING AND STORAGE RELATIVE HUMIDITY up to 95 wet bulb temp 35o C non condensing FUSE Quick acting 6 3A 250V 5 2 x 20mm San O P N EQ6 3A Kepco P N 541 0113 DIMENSIONS See Figure...

Отзывы: