PUT and COMMON power terminals on the rear
panel (see Figure 3). OUT S and COM S terminal of
the Monitor and Sensing Terminal block are for con-
nection of remote sensing leads (after removing the
factory-installed local sensing links). 

NOTE: Output

Sense lines must be connected for proper opera-
tion, either locally, or at the load (remote).

 Also

use OUT S and COM S to monitor voltage at the
load using external equipment such as a DVM, oscil-
loscope, etc. Use OUT MON and COM MON to
monitor voltage at the BOP output.

It is critical that configurations comprised of BOP,
load, and external programming devices, have a sin-
gle earth-ground point. Observe the following cau-
tion and refer to the applicable BOP 1KW-MG
Operator Manual for earth-ground recommenda-
tions. 

Failure to observe this caution will void the

warranty!

CAUTION: Never connect both the load
terminal tied to the BOP COM terminal
and the programming device common
to earth-ground. This compromises
accuracy and will cause catastrophic
damage to the BOP if the connection
between BOP COM and the load termi-
nal tied to earth-ground is lost.

LOCAL SENSING (FACTORY DEFAULT). 

Unit is shipped with local sensing links installed:
OUT S connected to OUT MON and COM MON
connected to COM S (see Figure 4A). 

REMOTE SENSING SELECT. 

First remove the

factory-installed local sensing links between OUT S
and OUT MON and between COM MON and COM
S. Then connect the OUT S and COM S lines at the
load (see Figure 4B) using #22 AWG wire, twisted
pair. 

ANALOG I/O CONNECTIONS. 

The Analog I/O

Port connector, located on the rear panel of the BOP
1KW power supply (see Figure 3), provides access
to analog programming inputs which can control the
mode of operation (voltage or current), output volt-
age or current, and establish positive and negative
voltage and current limits. An output analog corre-
sponding to output current is also provided. Refer to
Operator’s manual for details. 

TRIGGER CONNECTIONS. 

 The Trigger Port

(see Figure 3) provides for an external trigger input
for use with SCPI *TRG and TRIG commands. Refer
to Operator’s manual for details. 

GPIB CONNECTIONS (MG SUFFIX). 

 Your

computer must have a GPIB interface card installed.
Connect the power supply to the computer’s GPIB
interface card. Use a standard GPIB interface cable
at the GPIB port on the rear panel (see Figure 3). 

The default GPIB address is 6; refer to the Opera-
tor’s Manual to change it.

LAN CONNECTIONS (ME SUFFIX ONLY). 

Connect the BOP 1KW to

 a Microsoft Windows-based

computer via the LAN connector (see Figure 3). Use a
standard ethernet cable whether using a router or hub,
or connecting the BOP 1KW directly to a computer.
The BOP 1KW-ME is Auto-MDI-X enabled and does
not require a crossover cable for direct connection. For
Unix and Safari connections see full Operator Manual
(refer to “Accessing Manuals.” on page 1).

FINDING KEPCO POWER SUPPLIES ON THE LAN

The PSfind utility can be downloaded from the
Kepco web site at:

www.kepcopower.com/drivers/drivers-dl3.htm#bop1k

 

This utility finds all operational Kepco power sup-
plies connected to the LAN and then shows the
MAC and IP addresses of the models found. 

To run the utility from your PC download the
psfind.zip file to your computer. Extract psfind.exe
from the zip file to a location of your choice, then
double-click psfind.exe to run the application. A
separate window opens as shown in Figure 1.
Once the search is completed, all found units are
displayed in the Select a Unit window (the MAC
address appears in parentheses). If you do not see
your device in the Select a Unit window or if the icon
to the left of the selected instrument is red (not
green), make sure it is turned on and connected to
the network, then click the Search Again button.

FIGURE 1.  PS FIND SCREEN

!

Содержание BOP 10-100MG/ME

Страница 1: ...units the GPIB interface is replaced with a LAN interface Unless otherwise noted this guide applies to both models ACCESSING MANUALS First determine your Firmware Version see below then download the B...

Страница 2: ...or current and a 1 to 10V input for the limit channels BOP models are suitable for driving inductive loads such as large magnets or motors and for exercising batteries They are also suitable for chara...

Страница 3: ...el 1 d c Output Range Closed Loop Gain Output Impedance Voltage 2 V d c Current A d c Voltage Channel GV V V Current Channel GI A V Voltage Mode Series R L Current Mode Parallel R C Rd c mOhms L H Rd...

Страница 4: ...4 228 1692 REV 8 090418 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP OUTPUT CHARACTERISTICS...

Страница 5: ...n to IEEE 1118 BITBUS port 142 0485 Kepco KMDLA 5P Kycon Inc IEEE 488 Cable 1 meter long For MG models only Connects BOP power supply to GPIB bus SNC 488 1 IEEE 488 Cable 2 meter long For MG models on...

Страница 6: ...operation voltage or current output volt age or current and establish positive and negative voltage and current limits An output analog corre sponding to output current is also provided Refer to Oper...

Страница 7: ...LS AND INDICATORS RS 232 CONNECTIONS Connect the BOP 1KW to a modem using a Null Modem patch cable at the RS 232 port located on the rear panel See Fig ure 3 A Null Modem cable is not required for old...

Страница 8: ...1355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 3 BOP 1KW SERIES REAR PANEL VIEW LINKS INSTALLED FOR LOCAL SENSING FIGURE 4 LOAD CONNECTION A LOCAL...

Страница 9: ...ng an item on the list and pressing the View Modify function key Menus and submenus will display a list of parameters with the top one high lighted The function key assignments can vary but generally...

Страница 10: ...g and output Calibration Voltage Current and External and Controls calibration Shows Firmware versions for Display Serial GPIB LAN and analog Power up Settings Mode Voltage Cur rent External Main chan...

Страница 11: ...channels one to set output voltage or current and one to set the corre sponding protection limit The main channel is deter mined by the MODE key in local mode which alternately selects either Voltage...

Страница 12: ...ral Setup menu then highlight Max Min Set tings 2 Press to enter the Max Min Settings submenu Figure 6 If a Password is required see Opera tor s Manual for instructions 3 Highlight the voltage or curr...

Страница 13: ...afety fea tures constant current type active electronic loads must be adjusted to zero and the BOP front panel LCD must read 0V minimum cur rent before handling the power supply to load connections Re...

Страница 14: ...flow during the OFF state Table 5 indicates how the power supply responds to a command to go from Output ON to OFF CONFIGURE LOAD TYPE To configure press from the power up screen then highlight Load T...

Страница 15: ...copower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 1 OF 2 20 000 508 00 21 439 544 54 22 800 579 11 21 564 547 73 22 000 558 79 23 863 606 12 18 235 463 16 18 985 482 21 1 4...

Страница 16: ...FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 2 OF 2 SLIDES TRAVEL DISTANCE 23 000 584 2 22 000 5...

Отзывы: