The Batcher is a programmable, microprocessor based unit which provides batch control, monitors fl ow
rate and controls the fl ow of processing liquids. Start/Stop controls can be used in conjunction with pre-
warn and fi nal relays to provide valve actuation or pump control. An optional confi guration offers stream-
lined preset adjustments, remote Start, Stop & Reset, and weighted averaging.
Features
❑
Pulse or Analog Input
❑
Display Batch, Rate or Grand Total
❑
Pulse Count Input up to 20 KHz
❑
16 Point Linearization
❑
8 Digit K-Factors for Rate and Total
❑
Security Lockout
❑
2-Way RS232/422 Communications
❑
NEMA 4X/IP65 Front Panel
❑
Scalable 4-20 mA Output
❑
Scaled Pulse Output
❑
Optional Confi guration Includes:
- Streamlined Preset Adjustment (Easy Preset)
- Remote Start, Stop and Reset
- Weighted Averaging
Application
The unit is normally used for batch control or inventory tracking. The display may be toggled between
batch, rate, and grand total. A programmable K-factor makes keying-in engineering units easy. The unit
accepts pulse, contact closures or analog inputs and provides two separate preset controls.
BATCHtrol II
Principle of Operation
The batcher receives an input from a pulse producing fl owmeter through a sensor. The user programs
the batcher to condition the incoming pulses signal and compute the batch fl ow and fl ow rate. A wide
variety of different functions can then be performed based on the programmed confi gurations such as
start/stop functions, totalizing, and/or fl ow rate monitoring. Several other inputs, outputs and functions are
available.
BATCHtrol II Series Technical Manual
Kessler-Ellis Products Co.
BATCHtrol II
Software Versions 8.x & 12.x
Installation and Operating Manual
99 Washington Street
Melrose, MA 02176
Phone
781-665-
1400
Toll Free 1-800-517-8431
Pulse or Analog Input
Display Batch, Rate or Grand Total
Pulse Count Input up to 20 KHz
16 Point Linearization
8 Digit K-Factors for Rate and Total
Security Lockout
2-Way RS232/422 Communications
NEMA 4X/IP65 Front Panel
Scalable 4-20 mA Output
Scaled Pulse Output
Optional Confi guration Includes:
- Streamlined Preset Adjustment (Easy Preset)
- Remote Start, Stop and Reset
- Weighted Averaging
Pulse Count Input up to 20 KHz
16 Point Linearization
8 Digit K-Factors for Rate and Total
8 Digit K-Factors for Rate and Total
NEMA 4X/IP65 Front Panel
Scalable 4-20 mA Output
Scaled Pulse Output
- Remote Start, Stop and Reset