OPTIONAL VENT ARANGEMENT:
USE Part
# B93089
DUAL CHECK VALVE KIT
INCLUDES CHECK VALVE FOR AN INSTALLATION INLINE WITH
FACTORY INSTALLED CHECK VALVE. THIS IS RECOMMENDED
FOR SAILBOAT THROUGH HULL INSTALLATIONS
Mount bottom pan
into counter cutout
first, using foam tape
only-
no screws
3/8” (10mm)
Diameter Vent
Pipe
Feed hose
through “vee”
opening
!
WARNING
GAS LEAKS, UNCONTROLLABLE FLAME
FAILURE TO INSTALL CHECK
VALVE(S) AS SHOWN MAY CAUSE
WATER DAMAGE TO COOK TOP
RESULTING IN GAS LEAKS AND
UNCONTROLLABLE FLAME
COCKPIT SOLE
≥3” (76mm)
Suggested Vent PERKO
506DPCHR (or similar)
passes through aft wall
of cabin trunk; vents into
cockpit at least 3”
(76mm) above cockpit
Fig. 6 – “Cockpit”
KISS
KISS
KISS
KISS
Vent Layout for Sailboats
“Thru-Hull”
KISS
KISS
KISS
KISS
Vent Layout for Sailboats
Bottom pan installed
in countertop
hbkvlk
hbkvlk
hbkvlk
hbkvlk
International, Inc.
© 2005
10
THIS VENTING METHOD DOES NOT
CONFLICT WITH ANY ABYC
STANDARD. CALL
=
=
=
=
hbkvlk
hbkvlk
hbkvlk
hbkvlk
=
=
=
=
(860) 664-4906 for copy of ruling
10 DEGREE SLOPE
TO DRAIN
GALLEY SOLE
CHECK VALVE
•
NOTE “FLOW” LABEL (INLET IS RED)
•
FACTORY INSTALLED
•
hbkvlk
# B93088 FOR REPLACEMENT ASSY.
•
OUTLET REQUIRES 5/8” ID HOSE
Not
included