Installation
Electrical Connection
5
Before proceeding further, verify that the
power supply is disconnected. Verify that
the appropriate electrical supply requirements
have been met. Please refer to the table on
page 16 for appropriate electrical
requirements. The cooktop is supplied
with a 36-inch long conduit for a connection to
an accessible junction box. The 240V conduit
consists of three insulated wires. There are
two insulated hot lead conductors (red and
black) and one insulated ground conductor
(green). The 120V conduit consists of three
insulated wires. There is the hot lead
conductor (black), the neutral conductor
(white) and one insulated ground conductor
(green).
Attach conductor wires to residence wiring in
accordance with national, state and local
electric codes.
WARNING!
The entire appliance must be grounded
at all times when the electrical power
supply is on. Do not ground the
appliance with the neutral house supply
wire (white). A separate ground must
be used.
6
Remove the plastic film from the cooktop.
Clean the cooktop before you use it for the
first time. A thorough cleaning with a
recommended cooktop cleaner (
Cerama
Bryte Ceramic Cooktop Cleaner
) will provide
a clean, shiny coating on the cooktop surface.
Final Preparations Prior
to Use
19