94
●
APPENDICES
1
Sets RIT OFF/ON or reads status.
RT
RIT
2
Parameter Format
Parameter function
P1
1
RIT OFF/ON
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
R
T P1
R
T P1
;
R
T
;
4
5
6
7
8
9 10 11 12 13 14
;
1
Sets or reads RF ATT(attenuator).
RA
RF ATTENUATOR
2
Parameter Format
Parameter function
P1
48
ATTENUATOR
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
R
A
P1
;
R
A
;
4
5
6
7
8
9 10 11 12 13 14
P1
R
A
;
1
Sets the RIT frequency shift to 0.
RC
2
Parameter Format
Parameter function
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
R
;
4
5
6
7
8
9 10 11 12 13 14
RIT CLEAR
C
Note:
This command also clears the XIT
frequency (same as RIT shift).
The command functions independently
from the RIT/XIT control.
1
Selects receive/transmit mode.
RX
2
Parameter Format
Parameter function
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
;
;
TX
RX, TX
RX/TX
RX/TX
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
Lowers/raises RIT frequency.
RD
2
Parameter Format
Parameter function
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
R
;
4
5
6
7
8
9 10 11 12 13 14
RU
RIT DOWN/UP
D/U
Note:
This command also affects the XIT
frequency (same as RIT shift).
The command functions independently
from the RIT/XIT control.
1
Sets Scan OFF/ON or reads status.
SC
SCAN
2
Parameter Format
Parameter function
P1
1
SCAN OFF/ON
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
S
C P1
S
C P1
;
S
C
;
4
5
6
7
8
9 10 11 12 13 14
;
1
Sets or reads RF gain.
RG
RF GAIN
2
Parameter Format
Parameter function
P1
31
RF GAIN
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
R G
P1
;
R G
;
4
5
6
7
8
9 10 11 12 13 14
P1
R G
;
1
Sets or reads Semi Break-in delay time.
SD
SEMI BREAK-IN DELAY TIME
2
Parameter Format
Parameter function
P1
49
SEMI BREAK-IN
DELAY TIME
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
S
D
P1
;
S
D
;
4
5
6
7
8
9 10 11 12 13 14
P1
S
D
;
1
Selects a meter function or reads meter values.
RM READ METER
2
Parameter Format
Parameter function
P1
24
METER SWITCH
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
R M P1
;
R M
;
4
5
6
7
8
9 10 11 12 13 14
P1
R M
;
P2
P2
22
METER VALUE
1
S-meter and TX RF meter readings.
SM
S-METER
2
Parameter Format
Parameter function
P1
22
S-METER
VALUE
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
S M
P1
;
S M
;
4
5
6
7
8
9 10 11 12 13 14
Содержание TS-870S
Страница 104: ......