TM-D710A/D710E
51
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
• 430MHz band 7) Frequency: 435.250MHz
E,M4
Frequency: 444.250MHz
K
SSG output: OFF
Set to the point where noise
will be muted by turning the
SQL knob (Band B).
SSG
Oscilloscope
TX/RX
unit
(Rear)
ANT
EXT.SP
Check
SQL knob (Band B) position:
8:00~11:00
BUSY icon disappear.
11:00
SQL knob
(Band B)
7:00 (MIN)
8:00
8) SSG output: –126dBm (0.11µV)
SSG MOD: 1kHz
SSG DEV: 3kHz
AF output: 0.63V/8
Ω
Squelch open.
BUSY icon appears and
S-meter display does not
appear.
5. S-meter
Check
Band A
• 144MHz band
S1
1) Frequency: 145.250MHz
E,M4
Frequency: 146.250MHz
K
SSG MOD: 1kHz
SSG DEV: 3kHz
SSG output
: –118dBm (0.28µV)±3dB
SSG
ANT
Check
One segment in S-meter
lights.
• 144MHz band
Full scale
SSG output
: –96dBm (3.54µV)±3dB
All segments in S-meter light.
• 430MHz band
S1
2) Frequency: 435.000MHz
E,M4
Frequency: 444.000MHz
K
SSG output
: –118dBm (0.28µV)±3dB
One segment in S-meter
lights.
• 430MHz band
Full scale
SSG output
: –96dBm (3.54µV)±3dB
All segments in S-meter light.
Band B
• 144MHz band
S1
3) Frequency: 145.250MHz
E,M4
Frequency: 146.250MHz
K
SSG MOD: 1kHz
SSG DEV: 3kHz
SSG output
: –118dBm (0.28µV)±3dB
One segment in S-meter
lights.
• 144MHz band
Full scale
SSG output
: –96dBm (3.54µV)±3dB
All segments in S-meter light.
• 430MHz band
S1
4) Frequency: 435.000MHz
E,M4
Frequency: 444.000MHz
K
SSG output
: –118dBm (0.28µV)±3dB
One segment in S-meter
lights.
• 430MHz band
Full scale
SSG output
: –96dBm (3.54µV)±3dB
All segments in S-meter light.