53
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-880
Transmitter Section
1. Frequency
1) Set test mode
Power meter Rear
ANT
Check
470.100MHz
±
100Hz
E,E4
Select “FREQ” in tuning mode. F. counter panel
419.100MHz
±
100Hz
E3
PTT : ON
2. Power
1) Maximum power
TX-RX
VR1
26.0W
E,E3
±
0.5W
E,E3
output
Set test mode
(A/2)
5.5W
E4
±
0.2W
E4
Select “HPOW” in tuning mode.
“H HPOW 256”
E
“H2 HPOW 250”
E3
“C HPOW 256”
E4
PTT : ON
3. High power
1) Set test mode
25.0W
E,E3
±
1.0W
E,E3
Select “HPOW” in tuning mode.
5.0W
E4
±
0.2W
E4
“L HPOW”
PTT : ON
2) “L2 HPOW”
PTT : ON
3) “C HPOW”
PTT : ON
4) “H2 HPOW”
PTT : ON
5) “H HPOW”
Set “H HPOW 250”
±
1.0W
E
PTT : ON
if you cannot adjust
+1.0W, –5.0W
E3
the output power to
±
0.2W
E4
25W for E3 type.
4. Low power
1) Set test mode
Power meter
6.0W
E,E3
±
0.5W
E,E3
Select “LPOW” in tuning mode.
1.0W
E4
±
0.1W
E4
“L LPOW”
PTT : ON
2) “L2 LPOW”
PTT : ON
3) “C LPOW”
PTT : ON
4) “H2 LPOW”
PTT : ON
5) “H LPOW”
PTT : ON
5. Power check 1) Set test mode
Power meter
ANT
Check
25W
±
1W, 8A or less
E,E3
CH : CH1 - Sig1
25W+1W, –5W (
E3
CH3 - Sig1)
CH2 - Sig1
Ammeter
DC IN
5W
±
0.2W, 5A or less
E4
CH3 - Sig1
PTT : ON
6. Modulation
1) Set test mode
Power meter Rear
ANT
Make the de-
(Wide 5k/Wide 4k/Narrow)
balance
MIC input : OFF
Deviation
panel
modulation
Select “BAL” in tuning mode. meter
waveform near.
“nL BAL”
Oscilloscope
Deviation meter filter
LPF : 15kHz
AF VTVM
Front
MIC
HPF : OFF
AG
panel
De-emphasis : OFF
2) “nC BAL”
PTT : ON
3) “nH BAL”
PTT : ON
4) “s BAL”
PTT : ON
5) “w BAL”
PTT : ON
Содержание TK-880 series