ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
52
TK-880
5. Squelch
1) Set test mode
SSG
Rear
ANT
(Tight)
Select “nL SQLT” in tuning mode.
panel
Set “nL SQLT 255”
AF VTVM
ACC
Distortion
(EXT.SP)
2) “nC SQLT”
meter
Set “nC SQLT 255”
Oscilloscope
AG
3) “nH SQLT”
Set “nH SQLT 255”
4) Only E type
“sL SQLT”, “sC SQLT”, “sH SQLT”
Same as narrow adjustment (255).
5) “wL SQLT”, “wC SQLT”, “wH SQLT”
Same as narrow adjustment (255).
6. RSSI (High)
1) Set test mode
Writing values only.
Select “nL HRSI” in tuning mode.
SSG freq’ : See freq’ table
SSG output : –70dBm
SSG MOD : 1.5kHz (Narrow)
2) “nC HRSI”
SSG freq’ : See freq’ table
3) “nH HRSI”
SSG freq’ : See freq’ table
4) “sL HRSI”, “sC HRSI”, “sH HRSI”
SSG freq’ : –70dBm
SSG output : Sensitivity
value of 12dB SINAD.
SSG MOD : 2.4kHz (Wide 4k)
5) “wL HRSI”, “wC HRSI”, “wH HRSI”
SSG freq’ : –70dBm
SSG output : Sensitivity
value of 12dB SINAD.
SSG MOD : 3.0kHz (Wide 5k)
7. Squelch
1) Set test mode
Check
Squelch must be opened.
check
CH : CH1 - Sig1
(Wide 5k/Wide 4k/Narrow)
SSG freq’ : See freq’ table
SSG output : 15dB SINAD level
2) SSG output : OFF
Squelch must be closed.
(Wide 5k/Wide 4k/Narrow)
8. QT check
1) Set test mode
Check
Squelch must be opened.
CH : CH1 - Sig5
(Wide 5k/Wide 4k/Narrow)
SSG freq’ : See freq’ table
SSG MOD
INT : 1kHz
EXT : 151.4Hz
SSG system MOD DEV
:
±
3.75kHz
SSG output : 12dB SINAD level
2) CH : CH1 - Sig4
Squelch must be closed.
CH1 - Sig6
CH1 - Sig7
Содержание TK-880 series
Страница 71: ...TK 880 TK 880 TK 880 95 BLOCK DIAGRAM ...