55
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-780/H
6. Modulation
1) Set test mode
Power meter Rear
ANT
Make the de-
(Wide/Narrow)
balanced
MIC input : OFF
Deviation
panel
modulation
Select “BAL” in tuning mode. meter
waveform neat.
“L BAL”
Oscilloscope
Deviation meter filter
LPF : 15kHz
AF VTVM
Front
MIC
HPF : OFF
AG
panel
De-emphasis : OFF
2) “C BAL”
PTT : ON
3) “H BAL”
PTT : ON
7. Maximum
1) Set test mode
3.8kHz (Wide)
±
50Hz (Wide/Narrow)
deviation
Connect AG to the MIC
1.75kHz (Narrow)
terminal.
(According to the
Select “MAX” in tuning mode.
, –)
“L MAX”
AG : 1kHz/50mV
Deviation meter filter
LPF : 15kHz
HPF : OFF
De-emphasis : OFF
PTT : ON
2) “C MAX”
PTT : ON
3) “H MAX”
PTT : ON
8. MIC
1) Set test mode
Check
±
3kHz
±
0.2kHz (Wide)
seisitivity
CH : CH1 - Sig1
±
1.5kHz
±
0.05kHz (Narrow)
check
AG : 1kHz/5mV
PTT : ON
9. QT deviation 1) Set test mode
0.75kHz (Wide)
±
50Hz (Wide/Narrow)
Select “FQT” in tuning mode.
0.35kHz (Narrow)
“L FQT”
Deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
2) “C FQT”
PTT : ON
3) “H FQT”
PTT : ON
10. DQT
1) Set test mode
0.75kHz (Wide)
±
50Hz (Wide/Narrow)
deviation
Select “F DQT” in tuning mode.
0.35kHz (Narrow)
“L FDQT”
Deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
2) “C FDQT”
PTT : ON
3) “H FDQT”
PTT : ON