TK-7180H/7182H
59
Test Equipment Required for Alignment
Test Equipment
Major Specifications
1. Standard Signal Generator
Frequency Range
136 to 174MHz
(SSG)
Modulation
Frequency modulation and external modulation
Output
0.1
µ
V to greater than 1mV
2. Power Meter
Input Impedance
50
Ω
Operation Frequency
136 to 174MHz or more
Measurement Capability
Vicinity of 50W
3. Deviation Meter
Frequency Range
136 to 174MHz
4. Digital Volt Meter
Measuring Range
1 to 20V DC
(DVM)
Accuracy
High input impedance for minimum circuit loading
5. Oscilloscope
DC through 30MHz
6. High Sensitivity
Frequency Range
10Hz to 600MHz
Frequency Counter
Frequency Stability
0.2ppm or less
7. Ammeter
13A or more
8. AF Volt Meter
Frequency Range
50Hz to 10kHz
(AF VTVM)
Voltage Range
3mV to 3V
9. Audio Generator (AG)
Frequency Range
50Hz to 5kHz
Output
0 to 1V
10. Distortion Meter
Capability
3% or less at 1kHz
Input Level
50mV to 10Vrms
11. Voltmeter
Measuring Range
10 to 1.5V DC or less
Input Impedance
50k
Ω
/V or greater
12. 4
Ω
Dummy Load
Approx. 4
Ω
, 20W
13. Regulated Power Supply
13.6V, approx. 20A (adjustable from 9 to 20V)
Useful if ammeter equipped
1
8
1 : BLC
2 : +B
3 : GND
4 : PTT/TXD
(PC serial data
from radio)
MIC connector (Front panel view)
5 : MICE
6 : MIC
7 : HOOK/RXD
(PC serial data
to radio)
8 : DM
Test cable for microphone input (E30-3360-08)
3
2
4
5
6
7
8
3
1
2
4
5
6
7
8
1
GREEN
RED
BLACK
BLUE
SHIELD
WHITE
GRAY
YELLOW
PTT
E
MIC-E
MIC
HK
Tuning cable (E30-3383-05)
Adapter cable (E30-3383-05) is required for inject-
ing an audio if PC tuning is used.
See “PC Mode” section fot the connection.
Lead wire +
MIC
Shield wire –
ADJUSTMENT (TK-7182H)