TK-2360
31
ADJUSTMENT
Receiver Section
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
1. Sensitivity
1) TEST CH: Low, Low’, Center,
High’, High (5 points)
SSG otuput : –70dBm
(70.8µV)
SSG MOD: 1.5kHz
SSG
DVM
Oscilloscope
AF VTVM
ANT
SP/MIC
connector
FPU
Write
2. Sensitivity
Check
[Narrow]
1) TEST CH: 2, 3
SSG otuput: –115dBm
(0.4µV)
SSG MOD: 1.5kHz
Check
13dB SINAD or more
[Wide]
2) TEST CH: 1
SSG otuput: –117dBm
(0.32µV)
SSG MOD: 3.0kHz
3. High RSSI
[Narrow]
1) TEST CH: Center, Low, High
(3 points)
SSG otuput: –70dBm
(70.8µV)
SSG MOD: 1.5kHz
FPU
Write
[Wide]
2) TEST CH: 1
SSG otuput: –70dBm
(70.8µV)
SSG MOD: 3.0kHz
4. Low RSSI
[Narrow]
1) TEST CH: Center, Low, High
(3 points)
SSG otuput: –118dBm
(0.28µV)
SSG MOD: 1.5kHz
[Wide]
2) TEST CH: 1
SSG otuput: –118dBm
(0.28µV)
SSG MOD: 3.0kHz
5. Open Squlch
[Narrow]
1) TEST CH: Center, Low, High
(3 points)
SSG otuput: –119dBm
(0.25µV)
SSG MOD: 1.5kHz
[Wide]
2) TEST CH: Center
SSG otuput: –120dBm
(0.22µV)
SSG MOD: 3.0kHz
6. Tight
Squelch
[Narrow]
1) TEST CH: Center, Low, High
(3 points)
SSG otuput: –115dBm
(0.40µV)
SSG MOD: 1.5kHz
[Wide]
2) TEST CH: 1
SSG otuput: –116dBm
(0.35µV)
SSG MOD: 3.0kHz