TK-2360
30
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
6. DTMF
Deviation
[Narrow]
1) TEST CH: 1
Deviation meter fi lter
LPF:
15kHz
HPF:
OFF
PTT:
ON
Power
meter
Deviation
meter
Oscilloscope
AG
AF VTVM
ANT
SP/MIC
connector
FPU
1.5kHz
±100Hz
[Wide]
2) TEST CH: 1
PTT:
ON
3.0kHz
±100Hz
7. MSK
Deviation
[Narrow]
1) TEST CH: 1
Deviation meter fi lter
LPF:
15kHz
HPF:
OFF
PTT:
ON
1.5kHz
±100Hz
[Wide]
2) TEST CH: 1
PTT:
ON
3.0kHz
±100Hz
8. Single Tone
Deviation
[Narrow]
1) TEST CH: 1
Deviation meter fi lter
LPF:
15kHz
HPF:
OFF
PTT:
ON
1.5kHz
±100Hz
[Wide]
2) TEST CH: 1
PTT:
ON
3.0kHz
±100Hz
9. QT
Deviation
[Narrow]
1) TEST CH: Center, Low, High
(3 points)
Deviation meter fi lter
LPF:
3kHz
HPF:
OFF
PTT:
ON
0.37kHz
±40Hz
[Wide]
2) TEST CH: 1
PTT:
ON
0.75kHz
±40Hz
10. DQT
Deviation
[Narrow]
1) TEST CH: 1
Deviation meter fi lter
LPF:
3kHz
HPF:
OFF
PTT:
ON
0.37kHz
±40Hz
[Wide]
2) TEST CH: 1
PTT:
ON
0.75kHz
±40Hz
11. Battery
Warning
Level
1) BATT terminal voltage: 5.9V
DVM
TX-RX
BATT
terminal
FPU
Write
BATT terminal voltage: 5.9V