* The SG-5260 i s rated to allow sett ing an output level in an EMF dB// range
of - 2 0 to 132dB/z , and a dBm range of - 133 to - 19dBm f o r 50Q
output impedance or — 1 3 4 . 8 to 17. 2dBm for 75Q output impedance. An
output level cannot be set outside those ranges.
4-2-2 DIRECT SETT ING
The set value can be input by using the LEVEL (dB) key @, the numeric keys
® , and the ENT key @.
1) When the LEVEL key @ i s pressed, d i g i t s a r e erased from the LEVEL
display and the ENT key' s LED flashes.
2) While the ENT key's LED i s f l a s h i n g , use the numeric keys to enter the
desired l e v e l value. I f a wrong d i g i t i s entered, press the BS key ®
to erase the d i g i t s one by one s t a r t i n g from the last input. Then enter
the correct value.
3) When the leve1 value has been s e t , press the ENT key. When the ENT
key i s p r e s s e d , the output l e v e 1 v a l u e d i s p l a y e d on the d i s p l a y i s
output.
4) S e l e c t e i t h e r EMF dB
fi
or dBm as output l e v e l u n i t by using the unit
selector switch @.
* I f a level value exceeding the range of the unit' s ratings i s entered, the
level display value wi11 return to the level value v a l i d before the input.
* During d i r e c t s e t t ing, do not press the keys other than the numeric keys
on the front panel.
* I f the ENT key i s not pressed a f t e r the s e t t ing and w h i l e i t s LED i s
f l a s h i n g , the set value returns to the value v a l i d before the input when
the LEVEL key ® i s pressed again.
4-2-3 DISPLAY UNIT CHANGE
To change the l e v e l u n i t , press the d i s p l a y unit s e l e c t o r s w i t c h ® . The
21