7
CAUTION
◆
Always switch OFF a transceiver equipped with a battery pack before inserting the
transceiver into the charger.
◆
Always remove the AC adapter from an AC outlet before attempting to inspect or clean
the charger. Removing the battery packs or changing the controls does not remove
the AC voltage from the charger.
◆
Position the AC adapter cable so it will not be stepped on, tripped over, nor subjected
to damage.
◆
Always remove the AC adapter from an AC outlet by pulling on the adapter rather than
the cable.
◆
Do not use the charger if it has a damaged AC adapter or adapter cable, or if the
charger has been damaged in any way. Contact your
KENWOOD
dealer to replace or
repair the damaged part.
4
When charging is completed, the indicator flashing green. Remove the battery
pack or the transceiver from the charging slot of the charger.
• It takes approximately 4.5 hours to charge the battery pack.
• When the charger will not be used for a long time, unplug the AC adapter
from the AC outlet.
Note:
◆
The ambient temperature should be between 41°F and 104°F (5°C and 40°C) while
charging is in progress. Charging outside this range may not fully charge the battery.
◆
The battery pack life is over when its operating time decreases even though it is fully and
correctly charged. Replace the battery pack.
LED Status
Indicator color
Meaning
Light Red
A transceiver is in the charging slot and charging has
started.
Flashing Red
the battery pack is either defective or the battery pack
contacts are not properly mated with those of the
charger.
Flashing Green
Charging is completed; remove the battery pack from
the charger.
Alternates flashing green and
orange
The temperature of the battery pack has not satisfied
the charging start temperature. Remove the battery
pack from the charger and wait until it reaches a
normal temperature before charging it again.