ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
DTMF
Deviation
*4
[Wide 4k]
1) Adj item: [As DTMF]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [DTMF
Deviation (Wide 4k)]
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Deviation
meter
Oscilloscope
ANT
[Panel
tuning
mode]
[ ],[ ]
[PC test
mode]
[ ],[ ]
Write the value as
followings.
650 (Reference
value)
2.30~2.50kHz
[Wide 5k]
1) Adj item: [Aw DTMF]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [DTMF
Deviation (Wide 5k)]
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
2.90~3.10kHz
12. MSK
Deviation
*4
[Narrow]
1) Adj item: [An MSK]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [MSK
Deviation (Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Write the value as
followings.
513 (Reference
value)
1.40~1.60kHz
[Wide 4k]
1) Adj item: [As MSK]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [MSK De-
viation (Wide 4k)]
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
2.30~2.50kHz
[Wide 5k]
1) Adj item: [Aw MSK]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [MSK De-
viation (Wide 5k)]
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
2.90~3.10kHz
13. CWID
Deviation
*4
[Very
Narrow]
1) Adj item: [Nv CWID]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [CWID
Deviation]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Write the value as
followings.
375 (Reference
value)
1.00~1.20kHz