1-40 (No.RA016<Rev.001>)
3-2.
Low
power
check
(Battery
voltage:
7.5V)
[700M
band talk
around]
1)CH-Sig: 1-1
PTT: ON
TA: ON
1)Test Channel
Channel: 1
Test Signaling Mode: Analog
Signaling: 1
PTT: Press [Transmit] button.
Power
meter
Ammeter
Panel ANT
Check
0.5W~1.5W
1.4A or less
2)CH-Sig: 2-1
PTT: ON
TA: ON
2)Test Channel
Channel: 2
Test Signaling Mode: Analog
Signaling: 1
PTT: Press [Transmit] button.
Power
meter
Ammeter
Panel ANT
Check
0.5W~1.5W
1.4A or less
3)CH-Sig: 3-1
PTT: ON
TA: ON
3)Test Channel
Channel: 3
Test Signaling Mode: Analog
Signaling: 1
PTT: Press [Transmit] button.
Power
meter
Ammeter
Panel ANT
Check
0.5W~1.5W
1.4A or less
3-3.
Low
power
check
(Battery
voltage:
7.5V)
[800M
band]
1)CH-Sig: 7-1
PTT: ON
TA: OFF
1)Test Channel
Channel: 7
Test Signaling Mode: Analog
Signaling: 1
PTT: Press [Transmit] button.
Power
meter
Ammeter
Panel ANT
Check
0.5W~1.5W
1.4A or less
2)CH-Sig: 8-1
PTT: ON
TA: OFF
2)Test Channel
Channel: 8
Test Signaling Mode: Analog
Signaling: 1
PTT: Press [Transmit] button.
Power
meter
Ammeter
Panel ANT
Check
0.5W~1.5W
1.4A or less
3)CH-Sig: 9-1
PTT: ON
TA: OFF
3)Test Channel
Channel: 9
Test Signaling Mode: Analog
Signaling: 1
PTT: Press [Transmit] button.
Power
meter
Ammeter
Panel ANT
Check
0.5W~1.5W
1.4A or less
3-4.
Low
power
check
(Battery
voltage:
7.5V)
[800M
band talk
around]
1)CH-Sig: 7-1
PTT: ON
TA: ON
1)Test Channel
Channel: 7
Test Signaling Mode: Analog
Signaling: 1
PTT: Press [Transmit] button.
Power
meter
Ammeter
Panel ANT
Check
0.5W~1.5W
1.4A or less
2)CH-Sig: 8-1
PTT: ON
TA: ON
2)Test Channel
Channel: 8
Test Signaling Mode: Analog
Signaling: 1
PTT: Press [Transmit] button.
Power
meter
Ammeter
Panel ANT
Check
0.5W~1.5W
1.4A or less
3)CH-Sig: 9-1
PTT: ON
TA: ON
3)Test Channel
Channel: 9
Test Signaling Mode: Analog
Signaling: 1
PTT: Press [Transmit] button.
Power
meter
Ammeter
Panel ANT
Check
0.5W~1.5W
1.4A or less
4.
MIC
sensitivity
check
1)CH-Sig: 1-1
AG: 1kHz
PTT: ON
1)Test Channel
Channel: 1
Test Signaling Mode: Analog
Signaling: 1
AG: 1kHz
PTT: Press [Transmit] button.
Deviation
meter
Oscillo-
scope
AG
AF VM
Panel ANT
Univer-
sal con-
nector
Adjust AG
input to get
a standard
MOD.
12.5mV
±5.8mV
Item
Condition
Measurement
Adjustment
Specifica-
tions
/Remarks
Panel test
mode
PC test mode
Test-
equipment
Unit Terminal Unit Parts
Method