1-72 (No.RA016<Rev.001>)
5.4
Replacing Main Unit
Main unit information
Method of confirming “Original Main unit” and “Service
Main unit”
Note:
• The 0
Ω
resistor (R1) is used to differentiate the destina-
tion with a visual check. These are not connected with any
PCB pattern; they are specifically for production control.
There is no need to change the mount of these resistors.
• There is no difference between the schematic diagram of
the Service Main unit (XC1-0321-81) and the schematic
diagram of the original Main unit (XC1-0321-80). (R1 is
connected with GND (ground) only.)
Supplied Accessories of “Service Main unit”
”Service Main unit” Data
The following data is written on the service unit:
After Changing the PCB
(1) After changing the printed circuit board, write the up-to-
date Firmware following the instructions in the “5.2 RE-
ALIGNMENT - 5.2.6 Firmware Programming Mode”.
• Write the Firmware in accordance to the Market. If you
write different Market Firmware, there are times com-
munication with the FPU is not possible.
(2) Using the KPG-D1/D1N, select your desired item (Model
Name and Frequency) from the Model> Product Infor-
mation menu, then use Program> Write Data to the
Transceiver to write the FPU data (PC Programming
mode). When writing to the transceiver, a Warning Mes-
sage, corresponding to the item selected, appears. Click
[OK] to continue writing the data.
(3) Enter Program> Test Mode, then adjust the various ad-
justment data (PC Test Mode) as described in the "SEC-
TION 4 ADJUSTMENT".
(4) Attach the new labels corresponding to the new printed
circuit board. (Refer to the images below for label place-
ment.)
(5) If necessary, write the FPU data used by the customer
with the KPG-D1/D1N.
Note:
• When using the ESN Validation function of NXDN Trunk-
ing, the NXDN ESN number changes when the circuit
board is changed (the number is written on the circuit
board); the NXDN Trunking System cannot be accessed.
Use the KPG-110SM on the NXDN Trunking System side
to reprogram the NXDN ESN number.
• When a new printed circuit board is used, the KENWOOD
ESN changes, as does the Transceiver Information dis-
play of the KPG-D1/D1N, but this does not have any effect
on the operation of the transceiver.
• If changing to the original ESN, please contact our service
center.
ESN Label Layout
Note:
Cut a UPC code and UPC barcode at dotted line.
Model Name
Original Main unit
Number
For Service Main
unit Number
NX-5400
XC1-0321-80
XC1-0321-81
Item (Including Parts Number)
Quantity
Main Unit (XC1-032)
1
KENWOOD ESN/ NXDN ESN/ Product
Number/ MPT ESN/P25 ESN Label
1
Data Type
Description
Firmware
NX-5400 Firmware.
FPU Data
(PC programming mode)
XC1-032 (NX-5400) F2, K2 type data.
Various Adjustment Data
(PC Test mode)
General adjustment values for the
XC1-032 (NX-5400).
KENWOOD ESN
Model name: [XC1-032] NX-5400S
Type: F2
The same number as the KENWOOD
ESN label is written.
NXDN ESN/ MPT ESN/
Product number/
P25 ESN
The same number as the NXDN ESN/
MPT ESN/Product Number/P25 ESN
label is written.
R1 SRV
R2 LCD
R3
R4
XC1-032
R1
1-80
0
(None)
1-81
XC1-032
Component side
The 0 resistor (R1) is mounted
on the "R1" silk print part of the
Service Main unit (XC1-0321-81)
ESN Label