(No.RA015<Rev.002>)1-113
5.4
Replacing Main Unit
Main unit information
Method of confirming “Original Main unit” and “Service
Main unit”
Note:
• The 0
Ω
resistor (R1, R2, R3) is used to differentiate the
destination with a visual check. These are not connected
with any PCB pattern; they are specifically for production
control. There is no need to change the mount of these re-
sistors.
• There is no difference between the schematic diagram of
the Service Main unit (XC1-0341-82/XC1-0341-83/XC1-
0370-12/XC1-0370-13) and the schematic diagram of the
original Main unit (XC1-0341-80/XC1-0341-81/XC1-0370-
10/XC1-0370-11). (R1, R2 and R3 are connected with
GND (ground) only.)
Supplied Accessories of “Service Main unit”
”Service Main unit” Data
The following data is written on the service unit:
After Changing the PCB
(1) After changing the printed circuit board, write the up-to-
date Firmware following the instructions in the “2.2 RE-
ALIGNMENT - 2.2.6 Firmware Programming Mode”.
• Write the Firmware in accordance to the Market. If you
write different Market Firmware, there are times com-
munication with the FPU is not possible.
(2) Using the KPG-D1/D1N, select your desired item (Model
Name and Frequency) from the Model> Product Infor-
mation menu, then use Program> Write Data to the
Transceiver to write the FPU data (PC Programming
mode). When writing to the transceiver, a Warning Mes-
sage, corresponding to the item selected, appears. Click
[OK] to continue writing the data.
(3) Enter Program> Test Mode, then adjust the various ad-
justment data (PC Test Mode) as described in the "SEC-
TION 4 ADJUSTMENT".
(4) Attach the new labels corresponding to the new printed
circuit board. (Refer to the images below for label place-
ment.)
(5) If necessary, write the FPU data used by the customer
with the KPG-D1/D1N.
Note:
• When using the ESN Validation function of NXDN Trunk-
ing, the NXDN ESN number changes when the circuit
board is changed (the number is written on the circuit
board); the NXDN Trunking System cannot be accessed.
Use the KPG-110SM on the NXDN Trunking System side
to reprogram the NXDN ESN number.
• When a new printed circuit board is used, the KENWOOD
ESN changes, as does the Transceiver Information dis-
play of the KPG-D1/D1N, but this does not have any effect
on the operation of the transceiver.
• If changing to the original ESN, please contact our service
center.
• KPG-D1N can't be used for E, E2 types.
Model Name
Original Main unit
Number
For Service Main
unit Number
NX-5300
(F2,F3,K2,K3)
XC1-0341-80
XC1-0370-10
XC1-0341-82
XC1-0370-12
NX-5300
(F5,F6,K5,K6,E.E2)
XC1-0341-81
XC1-0370-11
XC1-0341-83
XC1-0370-13
Item (Including Parts Number)
Quantity
Main Unit (XC1-034, XC1-037)
1
KENWOOD ESN/ NXDN ESN/ Product
Number/ MPT ESN/P25 ESN Label
1
Data Type
Description
Firmware
NX-5300 Firmware.
FPU Data
(PC programming mode)
XC1-034/XC1-037 (NX-5300) F2, F5,
E2 type data.
Various Adjustment Data
(PC Test mode)
General adjustment values for the
XC1-034/XC1-037(NX-5300).
R1 SRV
R2 LCD
R3
R4
XC1-034
XC1-037
Component side
The 0 resistor (R1) is mounted
on the "R1" silk print part of the
Service Main unit (XC1-0341-82/
XC1-0341-83/XC1-0370-12/XC1-0370-13).
XC1-037
0-10
0-11
0-12
0-13
0
0
0
0
0
0
XC1-034
R1
1-80
(None)
R2
(None)
(None)
R3
(None)
(None)
1-81
1-82
1-83
(None)
KENWOOD ESN
Model name: [XC1-034/XC1-037]
NX-5300S1 (F2, K2:450~520MHz) or
NX-5300S2 (F5, K5:380~470MHz,
E2:400~470MHz)
Type: F2, F5, K2, K5, E2
The same number as the KENWOOD
ESN label is written.
NXDN ESN/ MPT ESN/
Product number/
P25 ESN
The same number as the NXDN ESN/
MPT ESN/Product Number/P25 ESN
label is written.
Data Type