![background image](http://html.mh-extra.com/html/kenwood/nexedge-nx-5300/nexedge-nx-5300_service-manual_191635100.webp)
1-100 (No.RA015<Rev.002>)
4. Sen-
sitivity 2
1) Adj item:
[An SENS2]
Adjust:[***]
2) Adj item:
[Low1]
→
[Low5]
→
[Center3]
→
[High2]
→
[High6]
SSG output:
-118dBm
(0.28
μ
V)
(MOD:
1kHz/±1.5kHz)
Adjust:[***]
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[Sensitivity 2]
2) Adj item:
[Low1], [Low5],
[Center3], [High2],
[High6]
SSG output:
-118dBm (0.28
μ
V)
(MOD:
1kHz/±1.5kHz)
Press [Apply All]
button to store the
adjustment value.
SSG
AF VM
Dummy
load
Panel ANT
Uni-
versal
con-
nector
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[
←
],
[
→
]
Write the value as follow-
ings.
Decrease the adjustment
value from 256 get 12dB
SINAD.
Note:
If the SINAD value is
more than 12dB SINAD
when “Sensitivity 2
[High6]” adjustment val-
ue is “256”, conduct the
following.
At first, apply “256” for
“Sensitivity 2 [High6]”
Next set SSG output:
-119dBm (0.25
μ
V). If
the SINAD value is less
than 12dB SINAD, finish
adjustment.
Otherwise, increase
“Sensivirity1 [High6]”
adjustment value from
“95” get 12dB SINAD.
5. RSSI
refer-
ence
1) Adj item:
[RRSSI]
Adjust:[***]
2) Adj item:
[Low1]
→
[Low5]
→
[Center3]
→
[High2]
→
[High6]
SSG output:
12dB SINAD level
-3dB
(MOD:
1kHz/±1.5kHz)
1) Adj item:
[RSSI Reference
(Analog Narrow)]
2) Adj item:
[Low1]
→
[Low5]
→
[Center3]
→
[High2]
→
[High6]
SSG output:
12dB SINAD level
-3dB
(MOD:
1kHz/±1.5kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
6. Open
Squelch
[Analog
Wide
5k]
1) Adj item:
[Aw SQL]
Adjust:[***]
2) Adj item:
[Low1]
→
[Low5]
→
[Center3]
→
[High2]
→
[High6]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 1kHz/
±3kHz)
1) Adj item:
[Open Squelch (An-
alog Wide 5k)]
2) Adj item:
[Low1]
→
[Low5]
→
[Center3]
→
[High2]
→
[High6]
SSG output:
12dB SINAD level at
Analog Narrow -3dB
(MOD: 1kHz/±3kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
Item
Condition
Measurement
Adjustment
Specifi-
cations
/Remarks
Panel tuning mode
PC test mode
Test-
equip-
ment
Unit
Ter-
minal
Unit
Parts
Method