ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
10. DQT
deviation
adjust
• Wide
1) Adj item: [W DQTW]
Adjust: [***]
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
2) Adj item: [WL DQTW]
→
[WC DQTW]
→
[WH DQTW]
Adjust: [***]
PTT: ON
Press [Orange] to store the ad-
justment value after adjustment.
Power
meter
Deviation
meter
Oscillo-
scope
AG
AF VTVM
Rear
panel
Front
panel
ANT
MIC jack
Front
panel
[B],[C] 0.75kHz
±50Hz
• Narrow
3) Adj item: [N DQTN]
Adjust: [***]
4) Adj item: [WL DQTN]
→
[WC DQTN]
→
[WH DQTN]
Adjust: [***]
PTT: ON
Press [Orange] to store the ad-
justment value after adjustment.
0.35kHz
±25Hz
11. DTMF
deviation
adjust
•Wide
1) Adj item: [W DTMW]
Adjust: [***]
Deviation meter fi lter
LPF: 15kHz
HPF: OFF
PTT: ON
Press [Orange] to store the ad-
justment value after adjustment
3.0kHz
±100Hz
• Narrow
2) Adj item: [N DTWN]
Adjust: [***]
PTT: ON
Press [Orange] to store the ad-
justment value after adjustment
1.5kHz
±50Hz
12. MSK
deviation
adjust
• Wide
1) Adj item: [W MSKW]
Adjust: [***]
Deviation meter fi lter
LPF: 15kHz
HPF: OFF
PTT: ON
Press [Orange] to store the ad-
justment value after adjustment
3.0kHz
±100Hz
• Narrow
2) Adj item: [N MSKN]
Adjust: [***]
PTT: ON
Press [Orange] to store the ad-
justment value after adjustment
1.5kHz
±50Hz
13. Single tone
deviation
adjust
• Wide
1) Adj item: [W 2TNW]
Adjust: [***]
Deviation meter fi lter
LPF: 15kHz
HPF: OFF
PTT: ON
Press [Orange] to store the ad-
justment value after adjustment
3.0kHz
±100Hz
• Narrow
2) Adj item: [N 2TNN]
Adjust: [***]
PTT: ON
Press [Orange] to store the ad-
justment value after adjustment
1.5kHz