• LCD display in the panel tuning mode
Adjustment
value (1~256)
Adjustment
item
W
TXF 256
W : Wide
N : Narrow
A : P25
■
Key operation
Key
Function
[
], [
]
Unused
[ ]
Exit the panel tuning mode and shift to the panel test
mode.
[ ]
TK-5710/5710H
Exit the 3 or 5 reference level adjustments without
backup.
TK-5810/5810H
Exit the 3, 5 or 7 reference level adjustments without
backup. If you press the [ ] key while the TX assist
voltage, RX assist voltage (Upper) and RX assist volt-
age (Lower) are selected, the 7 reference level adjust-
ment is performed automatically. When the automatic
adjustment is completed, the
icon appears on the
LCD. Additionally, even if you press the [ ] key after
entering the 7 reference level adjustment, the auto-
matic adjustment is not performed.
[S]
Back to the last adjustment item (The current adjust-
ment data is cleared.)
[A]
Go to the next adjustment item (The current adjust-
ment data is cleared.)
[B]
Push: Adjustment value down
Hold: Adjustment value continuation down
[C]
Push: Adjustment value up
Hold: Adjustment value continuation up
[Orange]
TK-5710/5710H
Enter the 3 or 5 reference level adjustments.
TK-5810/5810H
Enter the 3, 5 or 7 reference level adjustments.
[PTT]
Transmit
■
3 or 5 reference level adjustments frequency
(TK-5710/5710H)
• Assist voltage adjustments
TX assist voltage
Tuning point
Display
TX (MHz)
Low
L
136.00000
Low’
LC
145.50000
Center
C
155.00000
High’
CH
164.50000
High
H
174.00000
RX assist voltage (Upper)
Tuning point
Display
RX (MHz)
Low
L
204.95000
Low’
LC
209.70000
Center
C
214.45000
High’
CH
219.20000
High
H
223.95000
RX assist voltage (Lower)
Tuning point
Display
RX (MHz)
Low
L
185.95000
Low’
LC
190.70000
Center
C
195.45000
High’
CH
200.20000
High
H
204.94750
• Adjustment items other than assist voltage
Tuning point
Display
RX (MHz)
TX (MHz)
Low
L
136.10000
136.00000
Low’
LC
145.60000
145.50000
Center
C
155.10000
155.00000
High’
CH
164.60000
164.50000
High
H
173.90000
174.00000
■
3, 5 or 7 reference level adjustments frequency
(TK-5810/5810H)
• 3 or 5 reference level adjustments frequency
(Adjustment items other than assist voltage)
Tuning
point
Display
K
K2
RX (MHz) TX (MHz) RX (MHz) TX (MHz)
Low
L
450.10000 450.00000 400.10000 400.00000
Low'
LC
467.60000 467.50000 417.60000 417.50000
Center
C
485.10000 485.00000 435.10000 435.00000
High'
CH
502.60000 502.50000 452.60000 452.50000
High
H
519.90000 519.95000 469.90000 470.00000
• 7 reference level adjustments frequency
(Assist voltage adjustments)
TX assist voltage
Tuning
point
Display
K
K2
TX (MHz)
Low
LLL
450.10000
400.10000
Low’’
LL
461.70000
411.70000
Low’
L
473.40000
423.40000
Center
C
485.10000
435.10000
High’
H
496.70000
446.70000
High’’
HH
508.30000
458.30000
High
HHH
519.90000
469.90000
ADJUSTMENT