![Kenwood DM-3090 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/kenwood/dm-3090/dm-3090_service-manual_191153028.webp)
DM-3090
ADJUSTMENT
8. TEST-PLAY mode
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the TIMER/DELETE
TIMER/DELETE
TIMER/DELETE
button. TEST-PLAY menu
[ T E S T _ P L A Y _ ]
Step 3
Press once the DISPLAY/
CHARAC button.
ADRES setting (Target address initial value is indicated)
[ A D R E S _ 0 0 5 0 ]
Press once the MD PLAY button.
During search the search output pin 11 is set to "H", and it is
returned to "L" when continuous playback is started.
Step 4
Continuous playback (pit section) (A C1 error indication)
[s
c
]
Continuous playback (groove section) (A C1 error indication)
[a
c
]
Step 5
Press once the DISPLAY
(A ADIP error indication)
[a
a
]
button.
Step 6
Press once the MD STOP button. TEST-PLAY menu
[ T E S T _ P L A Y _ ]
Step No.
Setting Method
Remarks
Display
• If the MD STOP button is pressed while the TEST-PLAY menu is displayed, TEST mode STOP state is set.
• If the MD PLAY button is pressed while the TEST-PLAY menu is displayed, continuous playback is started from the current pickup position.
• Whenever the
button is pressed in the address setting mode, the address changes as follows.
0 0 5 0
→
0 3
0
→
0 7 0 0
→
0 8 A 0
→
0 0 5 0
→
…………
• Whenever the
button is pressed in the address setting mode, the digit which is changed with -
/
+ changes
as follows.
0 0 5 0
→
0 0 5 0
→
0 0 5 0
→
0 0 5 0
→
…………
• The digit of address which has been specified with -
/
+ and DISPLAY/CHARACTER button in the address setting mode is set to +01H/
-01H.
* If the -
/
+ button is held down, the setting changes continuously with 100 ms cycle.
• If the TRACK EDIT button is pressed in the continuous playback mode, the number of jump lines changes as follows.
1 line
→
10 line
→
400 line
→
1 line
→
…………
* After the number of jump lines is indicated for one second, the address indication is restored.
[
T R _ J U M P ]
• If the -
/
+ button is pressed in the continuous playback mode, the specified number of lines is jumped in the FWD/REV
direction.
* If the -
/
+ button is held down, the setting changes with 100 ms cycle.
• Whenever the CD STOP button is pressed in the continuous playback mode, the indication changes as follows.
* Pit section Continuous playback (SUBQ address indi C1 error indication) remains.
* Groove section
Continuous playback (ADIP address indi C1 error indication) remains.
↓
Continuous playback (ADIP address indi ADIP error indication) remains.
↓
Continuous playback (ADIP address indi C1 error indication) remains.
↓
•
: Adress,
: Error late,
: Jump lines
…
…
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button six times.
MANUAL adjustment menu
[ _ M N U _ A J S T _ ]
Step 3
Press once the MD PLAY button. Initial setting
→
Temperature measuring mode
[ T M P : _
_ _ _ ]
Step 4
Press once the ENTER button.
Laser ON
[ L O N : _ _ _ _ _ _ ]
Step 5
Press once the ENTER button.
Innermost periphery move
→
Tracking ATT (E signal) setting
[ P E G :
]
Step 6
Press once the ENTER button.
Tracking ATT (F signal) setting
[ P F G :
]
Step 7
Press once the ENTER button.
Indication of tracking EFMIO measurement (pit section)
[ P M I :
_ _ _ ]
Step 8
Press once the ENTER button.
Focus ATT (A signal) setting
[ L A g :
]
Step 9
Press once the ENTER button.
Focus ATT (B signal) setting
[ L B g :
]
Step 10
Press once the ENTER button.
Outside periphery move
→
Track closs setting
[ G C G :
]
Step 11
Press once the ENTER button.
Tracking ATT (E signal) setting
[ G E G :
]
Step 12
Press once the ENTER button.
Tracking ATT (F signal) setting
[ P F G :
]
Step 13
Press once the ENTER button.
Indication of tracking EFMIO measurement (groove section)
[ G M I :
_ _ _ ]
Step 14
Press once the ENTER button.
Focus ATT (A signal) setting
[ L A G :
]
Step 15
Press once the ENTER button.
Focus ATT (B signal) setting
[ L B G :
]
7.
High reflection disc
Step No.
Setting Method
Remarks
Display
• If the MD STOP button is pressed while the MANUAL adjustment menu is displayed, the state is changed to the TEST mode STOP
state.
• If the REC button is pressed, the setting returns step by step excepting the following case.
Track closs ATT setting (GTG)
→
Innermost periphery move
→
Focus ATT (B signal) setting (LBg)
28
DM-3090(K)
COVER
97.11.29
0:19
AM
y [ W
29
Содержание DM-3090
Страница 31: ...DM 3090 31 PARTS DESCRIPTIONS ...