![Kenwood DM-3090 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/kenwood/dm-3090/dm-3090_service-manual_191153027.webp)
DM-3090
27
ADJUSTMENT
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button five times.
MANUAL auxiliary adjustment mode
[ _ M N U _ Y O B I _ ]
Step 3
Press once the MD PLAY button. Initial setting
→
Temperature measuring mode
[ T M P : _
_ _ _ ]
Step 4
Press once the ENTER button.
Offset "0" setting
→
A signal offset tentative measurement
[ H A o :
_ _ _ ]
Step 5
Press once the ENTER button.
B signal offset tentative measurement
[ H B o :
_ _ _ ]
Step 6
Press once the ENTER button.
E signal offset tentative measurement
[ H E o :
_ _ _ ]
Step 7
Press once the ENTER button.
F signal offset tentative measurement
[ H F o :
_ _ _ ]
Step 8
Press once the ENTER button.
Offset tentative measurement
→
Laser ON
[ L O N : _ _ _ _ _ _ ]
Step 9
Press once the ENTER button.
Innermost periphery move
→
RF side FG rough adjustment
[ R F g :
_ _
]
Step 10
Press once the ENTER button.
Focus ATT (A signal) tentative setting
[ S A g :
]
Step 11
Press once the ENTER button.
Focus ATT (B signal) tentative setting
[ S B g :
]
Step 12
Press once the ENTER button.
RF side pit section TG adjustment
[ P T G :
_ _
]
Step 13
Press once the ENTER button.
Pit section COUT level setting
[ P C H :
_
]
Step 14
Press once the ENTER button.
Outer periphery move
→
RF side groove TG adjustment
[ G T G :
_ _
]
Step 15
Press once the ENTER button.
Groove section COUT level setting
[ G C H :
_
]
Step 16
Press once the ENTER button.
RF side TCRS adjustment
[ R C G :
_ _
]
Step 17
Press once the ENTER button.
Tracking ATT (A signal) setting
[ S E G :
]
Step 18
Press once the ENTER button.
Tracking ATT (B signal) setting
[ S F G :
]
Step 19
Press once the ENTER button.
Indication of tracking EFMIO measurement
[ g M I :
_ _ _ ]
Step 20
Press once the ENTER button.
RF side pit section FG adjustment
[R F G :
_ _
]
Step 21
Press once the ENTER button.
Focus ATT (A signal) setting
[ S A G :
]
Step 22
Press once the ENTER button.
Focus ATT (B signal) setting
[ S B G :
]
Step 23
Press once the ENTER button.
Offset "0" setting
→
A signal offset measurement
[ H A O :
_ _ _ ]
Step 24
Press once the ENTER button.
B signal offset measurement
[ H B O :
_ _ _ ]
Step 25
Press once the ENTER button.
E signal offset measurement
[ H E O :
_ _ _ ]
Step 26
Press once the ENTER button.
F signal offset measurement
[ H F O :
_ _ _ ]
Step 27
Press once the ENTER button.
TCRS signal offset measurement
[ T C O :
_ _ _ ]
Step 28
Press once the ENTER button.
A signal offset measurement
[ L A O :
_ _ _ ]
Step 29
Press once the ENTER button.
B signal offset measurement
[ L B O :
_ _ _ ]
Step 30
Press once the ENTER button.
E signal offset measurement
[ L E O :
_ _ _ ]
Step 31
Press once the ENTER button.
F signal offset measurement
[ L F O :
_ _ _ ]
5. MANUAL auxiliary adjustment mode (only low reflection disc)
Step No.
Setting Method
Remarks
Display
•
: Measurement value,
: Set value,
: Account value
• If the jog key upward/downward is pressed during setting indication, the setting increases/decreases, and the new setting is stored in RAM.
• If the REC button is pressed, the setting returns step by step excepting the following case.
A signal offset (HAO)
→
Offset tentative setting
→
RF side FG adjustment (RFG)
RF side TCRS adjustment (RCG)
→
RF side groove TG adjustment (GTG)
RF side groove TG adjustment (GTG)
→
Innermost periphery move
→
RF side pit section adjustment (PTG)
RF side pit TG adjustment (PTG)
→
RF side FG rough adjustment (RFg)
→
Laser lighting (LON)
Laser lighting (LON)
→
Offset "0" setting
→
A signal offset tentative measurement (HAo)
If the measurement value is within the OK range, " " appears on the 8th character.
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button six times.
MANUAL adjustment menu
[ _ M N U _ A J S T _ ]
Step 3
Press once the MD PLAY button. Initial setting
→
Temperature measuring mode
[ T M P : _
_ _ _ ]
Step 4
Press once the ENTER button.
Laser ON
[ L O N : _ _ _ _ _ _ ]
Step 5
Press once the ENTER button.
Innermost periphery move
→
Tracking ATT (E signal) setting
[ P E G :
]
Step 6
Press once the ENTER button.
Tracking ATT (F signal) setting
[ P F G :
]
Step 7
Press once the ENTER button.
Indication of tracking EFMIO measurement
[ P M I :
_ _ _ ]
Step 8
Press once the ENTER button.
Focus ATT (A signal) setting
[ H A G :
]
Step 9
Press once the ENTER button.
Focus ATT (B signal) setting
[ H B G :
]
6. MANUAL adjustment mode
High reflection disc
Step No.
Setting Method
Remarks
Display
• If the MD STOP button is pressed while the MANUAL adjustment menu is displayed, the state is changed to the TEST mode STOP
state.
• If the REC button is pressed, the setting returns step.
DM-3090(K)
COVER
97.11.29
0:19
AM
y [ W
32
Содержание DM-3090