P A N E L CONTROLS AND T H E I R FUNCTIONS
FRONT PANEL
(1) A C
T h i s is
the vertical input terminal coupled to
V . A T T
(4) through a capacitor to cut off D C component
contained in vertical input signal. It is used
on-fy
when A C component is to be observed.
(2) G N D
T h i s is the earth terminal for vertical input signal.
(3)
DC
T h i s
is
the vertical input terminal directly coupled to
V . A T T ( 4 ) . It is used to observe vertical input signal
containing D C component.
(4) V E R T A T T
T h i s is the vertical attenuator. It is used to attenuate
a signal voltage fed to A C terminal (1) or D C terminal
(3) to the amplitude suited for observation on C R T
screen.
When it is set to the 1 position, the signal fed to A C
terminal (1) or D C terminal (3) is directly fed to the
vertical amplifier. A t the 1/10 or 1/100 position, the
waveform amplitude is reduced to 1/10 or 1/100. A t
the G N D position, the input of the vertical amplifier
is connected to the earth.
(5) POWER
T h i s is the power switch. T o turn on the power, pull
4