![Kenwood CK 414 Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/kenwood/ck-414/ck-414_instructions-for-use-manual_189997042.webp)
42
ELECTRICAL FEEDER CABLE CONNECTION
To connect the supply cable:
- Remove the screws securing the cover “
A
” on the rear of the cooker (fig. 11.1).
- Feed the supply cable through the cable clamp “
D
”. The supply cable must be of a
suitable size for the current requirements of the appliance; see the section “Feeder
cable section”.
- Connect the wires to the terminal block “
B
” as shown in the diagram in figure 11.2;
or connect the phase wires to the terminal block “
B
” and the earth wire to the terminal
PE as shown in figure 11.1.
- Take up any slack in the cable and secure with the cable clamp “
D
”.
- Replace the cover “
A
”.
N.B.
The earth conductor must be left about 3 cm longer than the others.
Fig. 11.1
D
B
PE
A
N
L
FEEDER CABLE SECTION TYPE
HO5RR-F
230 V
3 x 2,5 mm
2
230 V
PE
N
L
1
(L
2
)
Fig. 11.2
PE
Earth
N
Neutral
L
Live