C-V100/V150/V300/V350
14
ADJUSTMENT
No.
ITEM
INPUT
SETTING
OUTPUT
SELECTOR
T U N E R / A M P
SETTING
ALIGNMENT
POINTS
ALIGN FOR
FIG.
SELECTOR : FM
1
DISCRIMINATOR
L31
↔
L32
(E, T only)
(A)
98.0MHz
1kHz, ±40kHz dev
(E, T type)
60dBu (ANT INPUT)
Connect a DC
voltmeter between
port of CN2
AUTO
98.0MHz
L31 (X05-)
0V
(a)
(B)
L32 (X05-)
Minimum
distrotion
2
DISTORTION
(STEREO)
(C)
98.0MHz
1kHz, ±40kHz dev
pilot: ±6kHz dev
60dBu (ANT INPUT)
(B)
AUTO
(98.0MHz)
IFT (W02-)
Mininum
distrotion
(a)
ANTENNA
AM
FM 75
Ω
GND
CONNECT WITH
POWER AMPLIFIER
SYSTEM
CONTROL
CD
AUX
TAPE 1/ MD
IN
IN
REC
PLAY
IN
TAPE 2
(MONITOR)
AUDIO
FRONT
REC
REC
PLAY
PLAY
MONITOR
OUT
SURROUND
VIDEO
CENTER
SUBWOOFER
UNSWITCHED
LD
/DVD
VCR
L
R
DVD 6CH.INPUT
DIGITAL IN DIGITAL IN
FM 50kHz
AM 9kHz
FM
100kHz
AM 10kHz
50
µ
s
75
µ
s
DE-
EMPHASIS
CHANNEL
SPACE
Oscilloscope
Distortion meter
AC voltmeter
Dummy antenna
(B)
(A)
(C)
(D)
AG
AG
FM SG
MPX
AG
FM SG
AM SG
(a)
ERROR MESSAGE
DISPLAY
DESCRIPTION
ERR 1
Main u-com sub clock no output
ERR 2
Main u-com sub clock frequency NG
C-V100(K) 1˜16pnew 97.7.15 7:34 PM ページ 14