background image

 

8

BUILT-IN SET-UP AND CALIBRATION ROUTINES –

 (available only at power-up) 

 
Displaying the firmware revision number (buttons 1 & 3) 

 
Power the unit on (plug into USB port) whilst holding buttons 1 & 3 pressed down. Allow a 
couple of seconds for the USB interface to initialise then release the buttons. Buttons 1 & 3 
should light up indicating this mode. The LED rings 1 to 4 indicate the firmware revision 
number in the following way: going clockwise from the left segment, the first 9 LEDs indicate 
the numbers 1 to 9 and a zero is indicated by the 15

th

 LED (the last one) . The revision number 

is a 4 digit number where  LED ring #1 indicates 1000s, LED ring #2 indicates 100s, LED ring 
#3 indicates 10s, and LED ring #4 indicates units. When you have read and noted the version 
number, press button #9 to start normal operation – the LED startup display will start. 

 
Resetting the unit to default values (buttons 2 & 4)  

 
To reset the unit to default values, power the unit on (plug into USB port) whilst holding buttons  
2 & 4 pressed down. Allow a couple of seconds for the USB interface to initialise then release 
the buttons. Buttons 2 & 4 should light up indicating this mode. The routine is complete when 
LED startup display starts. The joystick should be re-calibrated after a reset.

 

 
Calibrating the joystick (buttons 3 & 5) 

 
The joystick will have been calibrated when the unit is manufactured, but should it need re-
calibrating due to wear and tear or a reset (above item), use the following procedure: 
1) power the unit on (plug into USB port) whilst holding buttons 3 & 5 pressed down. Allow a 
couple of seconds for the USB interface to initialise then release the buttons. Buttons 3 & 5 
should light up indicating this mode. 
2) when the LED ring around knob #1 is lit (all 15 LEDs) the centre position of the joystick has 
been captured for both the X & Y axis. 
3)  move the joystick to the far right then move the joystick in a wide circle 

clockwise

     as you do this, the left, then the right segments of the LED rings will light up to indicate that  
     a value has been captured for this position. The positions requiring capture are right, 
     down, left, and up. It will not register the next position until the previous one in the  
     sequence has been successfully captured, so hold at each stage until the LED ring  
     indicates capture. New capture values must be at least equal to the previous capture value  
     for that position. 
4)  You need to capture each value 4 times to complete the sequence, by which time all 9 of  
      the LED rings will be fully lit.  
5)  The unit will then perform some calculations and store the values, and then the LED  
      startup display starts. 
 

Configuring extra operational modes (buttons 6 & 8) 

 
Described on page 5. 
 

UPGRADING THE KILLAMIX-MINI FIRMWARE (buttons 7 & 9) 

 
Before starting you should have the SysEx upgrade file ready on your computer. You will also 
need software on your computer that can send SysEx dump files (.syx format) 

We very 

strongly recommend using MIDI-OX if using a PC

Important - if you are using a laptop 

or portable computer, ensure that it is powered from the mains for the duration of this 
operation. Read through all the following instructions before starting this operation.

 

Содержание KILLAMIX-MINI

Страница 1: ...MIX MINI COMPACT USB CONTROLLER User Manual Serial numbers N2 0433 onwards non click encoders Suitable for use only with computers running Windows XP Vista 7 Mac OS X 10 2 onwards Linux kernel 2 5 onw...

Страница 2: ...l interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televis...

Страница 3: ...knob will change the MIDI transmit channel to that indicated beneath it so pressing knob 9 the rightmost one will select MIDI channel 9 The LED above the knob will light to indicate the current chann...

Страница 4: ...operational modes section on page 6 There is also a calibration routine built in which can be used if the joystick goes out of calibration due to wear and tear Again see page 6 The USB port The USB s...

Страница 5: ...ow plug the USB cable back in whilst holding push buttons 6 8 pressed down Allow a couple of seconds for the USB interface to initialise then release the buttons Push button 9 will light up to indicat...

Страница 6: ...all 3 button modes on only on off toggle Button 4 Hi Speed Encoder mode Off normal 3 speed operation default On hi speed mode active Hi Speed mode is implemented so that turning the encoder VERY slow...

Страница 7: ...uttons 50 to 58 joystick 59 60 61 62 5 offset by 50 knobs go 51 to 59 buttons 60 to 68 joystick 69 70 71 72 6 offset by 60 knobs go 61 to 69 buttons 70 to 78 joystick 79 80 81 82 7 offset by 70 knobs...

Страница 8: ...the unit on plug into USB port whilst holding buttons 3 5 pressed down Allow a couple of seconds for the USB interface to initialise then release the buttons Buttons 3 5 should light up indicating thi...

Страница 9: ...or upgrade not blank error state see error 4 info below 12345 Ready to receive SysEx dump file 123456 Correct SysEx file dump header identified waiting for rest of file 1234567 Checksum failed error s...

Страница 10: ...sure that the computer is running from the mains supply If power fails during the final copy operation after pressing button 9 and before buttons 1 to 8 go out leaving button 9 only lit then the Killa...

Страница 11: ...MIDI channel 1 16 Firmware upgrade SysEx dump only Connection USB mini B 5 pin socket on left side of unit Power USB Bus powered Power consumption 100mA in normal operation Finish Brushed aluminium wi...

Страница 12: ...the sustainable re use of material resources Household users should contact either the retailer where they purchased the product or their local government office for details of where and how they can...

Отзывы: