background image

Drawing

Part No

Description

1

FE190-001

Dec Fire inlet gas pipe - 700

 

FE190-002

Dec Fire inlet gas pipe - 800/900

2

FE190-005

Dec Fire Maxitrol regulator LPG

 

FE190-006

Dec Fire Maxitrol regulator NG

3

FE190-008

Dec Fire manual control valve

4

FE190-011

Dec Fire pilot gas pipe - mod 700

 

FE190-012

Dec Fire pilot gas pipe - mod 800/900

5

FE190-013

Dec Fire pilot assembly - jetted for lpg

 

FE190-014

Dec Fire pilot assembly - jetted for ng

6

FE190-015

Dec Fire electrode

7

FE190-016

Dec Fire t-couple 600mm long

8

FE190-019

Dec Fire burner gas pipe - mod 700

 

FE190-020

Dec Fire burner gas pipe - mod 800/900

9

FE190-021

Dec Fire tee piece 3/8" compression

10

FE190-022

Dec Fire tee pipe - mod 800/900

11

FE190-023

Dec Fire orifice/test point tee fitting

 

FE190-024

Dec Fire 5mm id test point o-ring

 

FE190-025

Dec Fire  test point screw  M5 x 8 pan

12

FE190-026

Dec Fire orifice elbow

 

 

Injectors

13

FE190-027

Dec Fire injector LPG B - 7 hole @ 0.65mm

 

FE190-028

Dec Fire injector LPG B - 7 hole @ 0.50mm

 

FE190-029

Dec Fire injector LPG B - 7 hole @ 0.55mm

 

FE190-030

Dec Fire injector NG B - 7 hole @ 0.95mm

 

FE190-031

Dec Fire injector NG B - 7 hole @ 0.75mm

 

FE190-032

Dec Fire injector NG B - 7 hole @ 0.85mm

14

FE190-033

Dec Fire aeration sleeve

 

 

Electrical Components

 

FE190-034

Dec Fire mains cordset

 

FE190-036

Dec Fire wiring loom  - 2 piece

 

FE190-037

Dec Fire P clip 20-PUC06A

 

FE190-038

Dec Fire cord clamp 21-MP6N4B

 

FE190-039

Dec Fire grommet

15

FE190-040

Dec Fire SPDT center off switch

16

FE190-041

Dec Fire 60 x 300  fan

 

FE190-042

Dec Fire 60 x 420 fan

 

 

Coals

 

FE190-047

Dec Fire bagged set of 36 coals

 

FE190-048

Dec Fire bagged set of 42 coals

 

FE190-049

Dec Fire bagged set of 48 coals

 

FE190-050

Dec Fire instruction book

 

FE190-051

Dec Fire dataplate label

9.

Содержание SIENNA KGF260-002

Страница 1: ...CORATIVE OPEN GAS FIRE Models KGF260 002 KGF260 005 KGF260 003 KGF260 006 KGF260 004 KGF260 007 Installation Servicing and Operation Manual INSTALLER These instructions must be left with the owner 1 2...

Страница 2: ...rtains clothes drapes furniture and other such material at least 900mm away from the appliance Never attempt to burn paper or any other material in the flames THE APPLIANCE SHALL BE INSPECTED BEFORE U...

Страница 3: ...of the fireplace and any building structure or other substantial immovable object in front of the fireplace 3 Model Gas Type Burner Pressure Gas Consumption KGF260 002 NG 1 00 kPa 30 5 MJ h KGF260 00...

Страница 4: ...55mm Installation into a wall cavity or false chimney The insert may be installed into a wall cavity or false chimney This shall be constructed generally as shown in the accompanying drawing of 75 x 5...

Страница 5: ...The chimney must be swept clean and any debris removed completely The size of the opening must be checked to ensure that the space is big enough to accommodate the insert Some bricks may need to be r...

Страница 6: ...y set the fascia panel may be attached to the casing using the magnets included Assembly of the burner The insert is factory assembled but it is necessary to place the coals onto the burner pan before...

Страница 7: ...again 2 To turn on the main burner turn the control knob to the HIGH position Always run the fireplace on HIGH for the first 10 minutes to warm up the fire and chimney and allow the chimney to draw pr...

Страница 8: ...eaks and the valve for correct smooth operation Check the ignition spark is strong and consistent Check the pilot for accumulation of dust or dirt Clean as required Do not attempt to ream or drill out...

Страница 9: ...id test point o ring FE190 025 Dec Fire test point screw M5 x 8 pan 12 FE190 026 Dec Fire orifice elbow Injectors 13 FE190 027 Dec Fire injector LPG B 7 hole 0 65mm FE190 028 Dec Fire injector LPG B...

Страница 10: ...th the owner s manual furnished with the product Any alterations or modifications including those affecting the product s performance operation safety durability or changes in its intended use Additio...

Страница 11: ...and address of the selling Dealer Please Note When travel to remote locations is required exceeding 35 km or 45 minutes the additional distance traveled will be chargeable to the customer by the Serv...

Страница 12: ......

Отзывы: