UV  Process

The UV light has shorter wavelength (higher energy) than the visible light. It is called ultra-violet 
because it is just beyond violet light in the light spectrum. Technically, the ultra-violet light is defined to 
be any wavelength of  light, which is shorter than 400  nanometer. 

UV rays, which penetrate into the micro-organisms, are absorbed by the DNA of  the pathogen in the 
water. The  DNA  is  altered  in  such  a  way  that  the  pathogen  cannot  reproduce  itself. Thus,  it  is 
essentially  killed  and  cannot  cause  infection.  This  process  of   DNA    modification    is    called   
inactivation. 

Reverse Osmosis Process

700

400

Wavelength(nm)

UVB

280-315

UVA

315-400

UVC

200-280

X-Rays

Ultraviolet

Visible

Infrared

Microwaves Radio

3

Marketed by:

KENT RO SYSTEMS LTD.

 

 

E-6, 7 & 8, Sector-59, Noida, U.P.-201 309, India.

Ph.: +91-120-3075000

E-mail: [email protected] | Website: www.kent.co.in 

Customer Care:  092-789-12345

The  Reverse  Osmosis  process,  also  known  as 
hyper filtration, is the finest filtration process known till 
date. The process ensures reduction of  particles as small 
as ions from a solution. Reverse Osmosis uses a semi-
permeable  membrane  to  reduce  salts  from  potable  / 
brackish  water.  In  Reverse  Osmosis,  water  pressure 
applied to the concentrated side forces the process of  
osmosis  into  reverse.  Under  enough  pressure,  treated 
water  is  "squeezed"  through  the  membrane  from  the 
concentrated side to the diluted side. Salts dissolved in 
water as charged ions are repelled by the RO membrane. 
The rejected impurities on the concentrated side of  the membrane are washed away in a 
stream  of   waste  water  and  thus do not  get  accumulated  as  in  a  traditional  filter.

KENT 

TM

 

PRIME MINERAL RO  WATER PURIFIER

Call from anywhere in India at

Service complaints can also be lodged on KENT SERVICE MOBILE APP for android phone

(Download by giving a missed call at 9212252852)

Auto-flushing  System

The  purpose  of   the Auto-Flushing  system  is  to  help  prevent  scaling  or  fouling  of   the  RO 
membrane by providing a rapid rinse which washes away impurities from the membrane's 
surface and keeps the membrane clean.  It offers following benefits.

Lowers rejected water outflow
Improves  "TDS" rejection rate i.e increases RO membrane efficiency
Extends life of  RO membrane

n
n
n

Содержание Prime Mineral RO

Страница 1: ...us at www kent co in Marketed by E 6 7 8 Sector 59 Noida U P 201 309 India Ph 91 120 3075000 E mail sales kent co in Website www kent co in KENT RO SYSTEMS LTD M LnK_KENT_2017_BOX MANUALS Manuals Prime manual_with_ISI New Size 5 5 8 25 dt 005 05 17 job no 1697 Kent Deta Hai Sabse Shudh Paani System Tested and Certified by WQA to NSF ANSI 58 for the reduction of Barium Fluoride Lead Nitrate Nitrite...

Страница 2: ...ree service To ensure that the warranty of your water purifier is effective it is important that you fill up the enclosed warranty card and mail us the installation report within 15 days of purchase In case you need any further information contact your nearest dealer branch Best Wishes KENT KENT KENT KENT RO SYSTEMS LTD Table of Contents 1 1 2 Salient Features 1 3 Items in the Box 1 4 Important In...

Страница 3: ...ter Municipal Corporation Water Supply Double treatment by RO UV processes controlled operations for enhanced purity and long life RO water recovery 50 Filter Change Alarm to indicate filter High Purification efficiency of 20 L hr replacement time Inbuilt auto flushing system UV FailAlarm to indicate failure in UV system Membrane with high flow RO Membrane fused inside membrane Inbuilt TDS Control...

Страница 4: ...es reduction of particles as small as ions from a solution Reverse Osmosis uses a semi permeable membrane to reduce salts from potable brackish water In Reverse Osmosis water pressure applied to the concentrated side forces the process of osmosis into reverse Under enough pressure treated water is squeezed through the membrane from the concentrated side to the diluted side Salts dissolved in water...

Страница 5: ...ade without prior written approval for products clogged by suspended matter precipitates or biological growth or for failures resulting from the lack of proper maintenance 10 KENT Purifiers or its ASP cannot and shall not be held liable for any sickness or illness due to the consumption of drinking water from any water purifier supplied by KENT Purifiers since KENT Purifiers or its ASP does not ha...

Страница 6: ...Installation Date Service Provider s Name Service Provider s Address Service Provider s Ph TDS of Raw Water By signing on this installation report the customer hereby agrees to the terms conditions of warranty mentioned on the back side of the warranty card Customer s Signature Service Provider s Stamp 4 Water Flow Diagram Electrical Circuit Diagram HF ...

Страница 7: ...h off the purifier and call the service technician for help The purifier will stop its purification process in such a circumstance 2 Sec 2 Sec 2 Sec 2 Sec Filter Change Alarm KENT TM Prime Mineral RO has an in built feature that sounds an audible alarm to indicate replacement time for filters This alarm will be audible after 700 hrs of use since the last filter change or since the time of installa...

Страница 8: ...ker on the wall preferably at 3 6 to 4 feet from the ground or as per convenience Step 02 Ensure that the sticker is pasted straight on the wall Drill holes as per the markings provided on the sticker Step 03 Using a hammer insert the puff up in the wall Step 04 Screw two 10 x 50 sized self taping screws 5 5 inches 140 mm apart horizontally Step 05 Install the tank on wall using screws Step 06 Con...

Страница 9: ...12 months It is recommended to frequency of the maintenance will greatly depend upon change the FRT when the filters are replaced the raw water quality and consumption of treated water Replace the RO membrane once in a year Storage tank must be drained once in 2 weeks To Replace the UV Lamp once in a year do so switch off the power supply open the drain If you are not going to use the purifier for...

Страница 10: ...n be converted to pentavalent arsenic in the presence of an effective oxidant such as free chlorine The arsenic in water containing detectable free chlorine or that has been treated with another effective oxidant will be in the pentavalent arsenic form 4Treatment with chloramine combined chlorine is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic Consumers ...

Отзывы: