manualshive.com logo in svg
background image

Two Year Limited Warranty 

 

SpectraPure, Inc. warrants each new Reverse Osmosis system to the original owner 

only to be free of defects in material and workmanship for a period of two years from 

the date of receipt. SpectraPure’s liabililty under this warranty shall be limited to 

repairing or replacing on SpectraPure’s option, without charge, F.O.B. SpectraPure’s 

factory, any product of SpectraPure’s manufacture. SpectraPure will not be liable for 

any cost of removal, installation, transportation, or any other charges which may 

arise in connection with a warranty claim. Products which are sold but not 

manufactured by SpectraPure are subject to warranty provided by the manufacturer 

of said products and not by SpectraPure’s warranty. SpectraPure will not be liable for 

damage or wear to products caused by abnormal operating conditions, accident, 

abuse, misuse, unauthorized alteration, or repair, or if the product was not installed 

in accordance with SpectraPure’s printed installation and operating conditions or 

damage caused by hot water, freezing, flood, fire, or acts of God.  

 

SpectraPure Inc. will not be responsible for any consequential damages arising from 

installation or use of the product, including any water damage due to flooding 

which may occur due to malfunction or faulty installation, including, but not limited 

to failure of installer to tighten all fittings. 

 

SpectraPure warrants (pro-rated) the performance of membrane elements for one 

year from date of receipt by the buyer, providing that the loss of performance was 

not caused by fouling, neglect, or water conditions exceeding the feed water pa-

rameters listed on page 3 of this manual. 

* Most municipal water supplies meet these requirements. 

Spectra

Pure

 

®

 

Spectra

Pure

®

Inc.   

215 S. Industrial Drive, Suite 2A  Tempe, Arizona  85281-2941 

480.894.5437        Call us toll-free  1.800.685.2783     

Fax  480.894.6109        Fax us toll-free  1.877.527.7873 

E-mail  [email protected]        Visit us on the web  www.spectrapure.com 

Terms and Conditions of Sale 

 

1.

To obtain service under this warranty, the defective system or components 

must be returned to SpectraPure with proof of purchase, installation date and 

failure date.  

2.

Any defective product to be returned to the factory must be sent freight 

prepaid; documentation supporting the warranty claim and/or a Return Goods 

Authorization must be included, if so instructed. 

3.

SpectraPure will not be liable for any incidental or consequential damages, 

losses, or expenses arising from installation, use, or any other causes. There are 

no expressed or implied warranties, including merchantability or fitness for a 

particular purpose, which extend beyond those warranties described or 

referred to above. 

4.

Some jurisdictions do not allow the exclusion or limitation of incidental or 

consequential damages and some jurisdictions do not allow limitations on how 

long implied warranties may last. Therefore, the above limitations or exclusions 

may not apply to you. This warranty gives you specific legal rights and you may 

also have other rights which vary jurisdiction to jurisdiction. 

5.

Method of Payment: All orders will be shipped C.O.D. or require payment in 

advance. 

6.

SpectraPure, Inc. reserves the right to change prices without notice when 

necessary. 

Eliminator 90  

Compact RO System 

Installation and Operating Manual 

 

Reverse Osmosis Water Purification System 

Spectra

Pure

 

®

 

REV - 1-25-2001 

Содержание Eliminator 90

Страница 1: ...s exceeding the feed water pa rameters listed on page 3 of this manual Most municipal water supplies meet these requirements SpectraPure SpectraPure Inc 215 S Industrial Drive Suite 2A Tempe Arizona 85281 2941 480 894 5437 Call us toll free 1 800 685 2783 Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com Terms and Conditions of ...

Страница 2: ...Production Rate Membrane Output Calculation 11 Temperature Correction Factor Table 11 Membrane Testing Testing the Quality of the Membrane 12 13 System Care Tips for Long Membrane Life 14 Storage 14 Choosing a Mounting Location 14 Replacement Parts 15 Warranty Terms and Conditions 16 Table of Contents SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com V...

Страница 3: ...ltra violet light from the sun and other sources such as metal halide lighting 2 Algae is more likely to thrive inside the clear filter housings when exposed to bright light 3 Avoid installing this unit in bright light or direct sunlight Temperature Extremes 1 The unit must be kept out of areas that are subject to freezing temperatures 2 High temperatures greater than 110 F 43 C must be avoided If...

Страница 4: ...etermine that the system is leak free 4 10 inch Granulated Activated Carbon Filter CF IN 10 Filter Diagram Encapsulated 90 GPD TFC RO Membrane TFCH 90 ENC SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com SpectraPure The following chart illustrates the procedure for determination of RO membrane performance Howeve...

Страница 5: ... in insuring that you get the best possible results from your new system Failure to perform this procedure will void the pro rated Membrane Warranty In order to maximize the life of your SpectraPure RO Membrane you may need to adjust the ratio of the concentrate to purified water If not enough concentrate is allowed to flow past the membrane during operation the impurities can concentrate and prec...

Страница 6: ...y tubing protruding from the end of the plug Flow Restrictor Removal Adjustment and Replacement Flow Restrictor Assembly capillary tubing translucent plastic insert yellow tubing 6 SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com SpectraPure Membrane Output Calculation Membranes produce the rated gallons per day...

Страница 7: ...ps of clean water into the fitting b Grasp the yellow tubing near the flow restrictor end and insert the tubing into the gray push fitting Push the tubing into the fitting until resistance is felt approximately 1 2 inch 12 7 mm The tubing in now resting on the o ring seal inside the fitting c Now firmly push the tubing approximately an additional 1 4 inch 6 35 mm further into the fitting to comple...

Страница 8: ... spectrapure com Visit us on the web www spectrapure com SpectraPure Place the flow restrictor in a safe location where it will not be accidentally crushed or damaged Re insert the blue black and yellow tubing into the push fittings of their respective ports on your replacement encapsulated membrane as described in the Removal Adjustment and Replacement section on page 7 line 6 a c See photo on pa...

Отзывы: