Section B – Page #12
NOV/2005
STEP ILLUSTRATION
STEP 6
Open the charge valve (21) on
the accumulator about one full
turn.
STEP 7
Open the valve on the nitrogen
tank.
Open the shut-off valve (12)
gradually, allowing nitrogen to
flow into the accumulator until the
charge kit pressure gauge (11)
reads the pressure determined
under Step 5, then close the shut-
off valve.
STEP 8
Close the charge valve (21) on
the accumulator and reinstall the
cap (19) and o-ring (20).
STEP 9
Remove the elbow end (18) of the
charge kit from the charge kit
adapter.