background image

INSTALLATION & OPERATING

INSTRUCTIONS

Inbuilt & Insert Wood Fires

CONTENTS

General Information........................................1

Testing & Approvals.........................................3

Installation..........................................3-7

Inbuilt Zero Clearance Box Installation.......8-9

Operation...............................................10-11

Maintenance........................................12

Replacement Parts..................................13-14

Warranty.................................................15

 

1. 

This fire must be installed by an approved installer, ideally registered with the New 

Zealand Home Heating Association. Do not allow any makeshift or compromising 

installation methods as this could result in a house fire. This Kent wood fire must be 

installed according to these instructions.

2. 

A  Building  Consent  from  the  Local  Authority  must  be  obtained  before  installing 

this  wood  fire,  and  we  suggest  that  the  Insurance  Company  covering  building 

insurance be advised of the installation.

3. 

This Kent wood fire, when installed according to these instructions, complies with 

the  provisions  of  AS/NZS  2918-2001  “Installation  of  Domestic  Solid  Fuel  Burning 

Appliances”.

4. 

The clearances given in these instructions are necessary to prevent overheating 

of nearby combustibles and drying out of the house structure. They may not be 

reduced without authorisation.

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

Important: the installer or seller must leave these instructions with the purchaser

GENERAL INFORMATION

Содержание KWF295-6937

Страница 1: ...nstructions 2 A Building Consent from the Local Authority must be obtained before installing this wood fire and we suggest that the Insurance Company covering building insurance be advised of the inst...

Страница 2: ......

Страница 3: ...for the wood fire to fix into the fireplace Refer to Table 1 Determine whether the flue pipe will fit vertically in the chimney from the heater to the cowl Install the selected Kent wood fire into th...

Страница 4: ...ake a permanent weatherproof seal Minimum Installation Clearances mm Model Model No A B C D E F G H I Rata KWF295 6938 25 500 300 200 840 59 2000 1200 160 Logfire II KWF295 6937 25 500 300 200 840 59...

Страница 5: ...two metres above the roof penetration it may be necessary to fit restraining guy wires for stability in high wind conditions The flue system should be vertical and without bends If an offset is requi...

Страница 6: ...ce Once in position and level fix the fire to the base of the fireplace enclosure with suitable anchors through the supplied fixing points in the base of the wood burners outer box Assemble the flue p...

Страница 7: ...in the correct position as wind and gusts hitting the flue and cowl system may cause back draft down the flue and into the home PRESSURE DIFFERENTIAL VENTING AND EXTERNAL AIR INTO THE BUILDING All fi...

Страница 8: ...59mm and must be a minimum of 785mm wide and 640mm deep behind the face of the wall with an additional 360mm forward of the wall face to allow for the front clearance once installed Timber framing aro...

Страница 9: ...ottom No substitutions may be made for these components Additional extension kits of 150mm 200mm and 250mm flue must be purchased to suit the particular installation At least three flue extension leng...

Страница 10: ...KLY TO BEGIN WITH Allow several small fires to build up a layer of ash in the wood fire and cure the paint before using maximum power NORMAL OPERATION ONCE THE FIRE IS ESTABLISHED The Kent wood fire r...

Страница 11: ...box completely Leave at least 25mm of ash in the bottom of the firebox after cleaning These ashes in the bottom of the wood fire assist the burning process by insulating the firebox and allowing air c...

Страница 12: ...he glass Remember that a properly operated wood fire will keep the glass clean by itself LUBRICATION The door hinges door handle spindle and air slide mechanism should be lubricated periodically with...

Страница 13: ...he temperature exposure Keep ember levels to the recommended height of more than 3cm below air tubes Replacing air tubes 1 Remove bricks from both sides 2 Remove the pin from the end of the old tube 3...

Страница 14: ...e safe to use KENT FIRE BRICKS Dimensions mm 2 205 x 176 x 25 4 180 x 176 x 25 KWF299 7040 Rata Logfire II KENT BAFFLES Includes Promat bricks Dimensions mm 480 x 200 KWF299 7043 Rata Logfire II The b...

Страница 15: ...fire must be installed with an approved flue system Failure to do so may void your warranty in its entirety The company is not liable for any consequential damage by a failure or defect covered in th...

Страница 16: ...ngs Ltd T A Aber 17 Mainstreet Place Te Rapa Hamilton 3200 Free Phone 0800 161 161 Free Fax 0800 163 163 www aber co nz Product specifications are at date of publication and are subject to change with...