background image

WARRANTY

KENT WARRANTY REGISTRATION

Please keep this copy for your records.

MODEL:…………………………………………………....................................................

SERIAL NUMBER:……………………………………………….........................................

RETAILER:…………………………………………………………….................................

PURCHASE DATE:………………………………………………..........................………..

INVOICE NUMBER:……………………………………....................................................

(Please keep your invoice attached to your warranty record)

INSTALLER NAME:…………………………………….………………......................…….

DATE INSTALLED:…………………………………………………..............................…...

NZ HOME HEATING

ASSOCIATION NUMBER:………………………….…………………......................…….

INSTALLER SIGNATURE:………………………………………………........................……

STANDARD WARRANTY

Your Kent wood fire is warranted for 10 years on the firebox with the exception of the 

following Kent parts: glass, glass seal, door seal, fire bricks, flue, secondary air system and 

removable baffle which will all have a 12 month warranty (parts only) provided they have 

been installed by an approved installer.  The warranty does not apply to normal wear 

and tear, misuse or neglect, nor if parts of the wood fire are replaced with non genuine 

Kent parts. Kent recommends an annual service and flue sweep with replacement of 

parts if recommended to obtain maximum life out of your wood burner.

CONDITIONS

Your Kent wood fire must be installed in accordance with the manufacturer’s instructions 

and  all  applicable  standards,  regulations  and  by-laws.  Your  Kent  wood  fire  must  be 

installed  with  an  approved  flue  system.  Failure  to  do  so  may  void  your  warranty  in  its 

entirety. The company is not liable for any consequential damage by a failure or defect 

covered  in  this  warranty.  All  claims  against  the  warranty  must  be  directed  in  the  first 

instance to the retail outlet from which you made your purchase. Any repairs undertaken 

without the express authority of Kent will invalidate this warranty. This warranty does not 

cover damage caused by wetbacks/water boosters, burning improper fuels (driftwood/

treated wood/coal or plastic-based waste), or installation, plumbing and sweeping work 

done by others (the installer is liable for any incorrect procedures or poor workmanship).

 

TRANSFERABILITY

Your Kent wood fire warranty is transferable on the sale of the home where the wood 

fire is installed. Nothing in this warranty is intended to limit any conditions of the warranty 

right or remedy pursuant to the Consumer Guarantee Act 1993, except to the extent 

permitted under the Act. Your Kent wood fire is intended for domestic use only and the 

warranty is not valid for wood fires to be used for business purposes. Kent reserves the right 

to alter or amend specifications or designs of its product without prior notice. 

15

Содержание KWF295-6937

Страница 1: ...nstructions 2 A Building Consent from the Local Authority must be obtained before installing this wood fire and we suggest that the Insurance Company covering building insurance be advised of the inst...

Страница 2: ......

Страница 3: ...for the wood fire to fix into the fireplace Refer to Table 1 Determine whether the flue pipe will fit vertically in the chimney from the heater to the cowl Install the selected Kent wood fire into th...

Страница 4: ...ake a permanent weatherproof seal Minimum Installation Clearances mm Model Model No A B C D E F G H I Rata KWF295 6938 25 500 300 200 840 59 2000 1200 160 Logfire II KWF295 6937 25 500 300 200 840 59...

Страница 5: ...two metres above the roof penetration it may be necessary to fit restraining guy wires for stability in high wind conditions The flue system should be vertical and without bends If an offset is requi...

Страница 6: ...ce Once in position and level fix the fire to the base of the fireplace enclosure with suitable anchors through the supplied fixing points in the base of the wood burners outer box Assemble the flue p...

Страница 7: ...in the correct position as wind and gusts hitting the flue and cowl system may cause back draft down the flue and into the home PRESSURE DIFFERENTIAL VENTING AND EXTERNAL AIR INTO THE BUILDING All fi...

Страница 8: ...59mm and must be a minimum of 785mm wide and 640mm deep behind the face of the wall with an additional 360mm forward of the wall face to allow for the front clearance once installed Timber framing aro...

Страница 9: ...ottom No substitutions may be made for these components Additional extension kits of 150mm 200mm and 250mm flue must be purchased to suit the particular installation At least three flue extension leng...

Страница 10: ...KLY TO BEGIN WITH Allow several small fires to build up a layer of ash in the wood fire and cure the paint before using maximum power NORMAL OPERATION ONCE THE FIRE IS ESTABLISHED The Kent wood fire r...

Страница 11: ...box completely Leave at least 25mm of ash in the bottom of the firebox after cleaning These ashes in the bottom of the wood fire assist the burning process by insulating the firebox and allowing air c...

Страница 12: ...he glass Remember that a properly operated wood fire will keep the glass clean by itself LUBRICATION The door hinges door handle spindle and air slide mechanism should be lubricated periodically with...

Страница 13: ...he temperature exposure Keep ember levels to the recommended height of more than 3cm below air tubes Replacing air tubes 1 Remove bricks from both sides 2 Remove the pin from the end of the old tube 3...

Страница 14: ...e safe to use KENT FIRE BRICKS Dimensions mm 2 205 x 176 x 25 4 180 x 176 x 25 KWF299 7040 Rata Logfire II KENT BAFFLES Includes Promat bricks Dimensions mm 480 x 200 KWF299 7043 Rata Logfire II The b...

Страница 15: ...fire must be installed with an approved flue system Failure to do so may void your warranty in its entirety The company is not liable for any consequential damage by a failure or defect covered in th...

Страница 16: ...ngs Ltd T A Aber 17 Mainstreet Place Te Rapa Hamilton 3200 Free Phone 0800 161 161 Free Fax 0800 163 163 www aber co nz Product specifications are at date of publication and are subject to change with...

Отзывы: