Step 7
To light the heater align the control knob with the “•” setting.
Push down fully on the control knob.
IMPORTANT:
• If the heater has been fitted with a new LPG cylinder
or has not been used for some time keep the knob
depressed for approximately 15 seconds to let air
escape (purge) from the gas hose and burner.
• If the heater has been used recently and has a cylinder
already fitted then move to step 8 with no delay.
Step 8
While still holding down the control knob fully, immediately
push the spark piezo button. You should hear a click and see
a small spark at the pilot flame (if the pilot and one burner
does not ignite, release the control knob and spark piezo
button, wait 30 seconds and repeat the procedure).
Step 9
Look at the pilot to confirm it is lit. If the pilot does not light,
release the control knob, wait 30 seconds and repeat the
procedure.
Step 10
Once the pilot is lit, continue to hold the control knob down
for a minimum of 5 seconds to allow the flame safety device
to heat up. Release the control knob completely. The pilot and
centre tile should remain alight.
Step 11
Allow the control knob to rise and then slightly depress and
rotate the knob to the desired heat setting.
For full heat – slightly depress knob, rotate to “• • •” position
- (3 tiles are lit).
For medium heat – slightly depress knob and rotate to
“• •” position - (2 tiles are lit).
For low heat – slightly depress knob and rotate to “•”
position - (1 tile is lit).
Step 12
Turning off the Heater
1. Stand to one side of the heater when turning it off.
NEVER stand directly in front of the heater when
attempting to turn off the heater. Take care that your
clothing is not in close contact with the safety guard or in
front of the heater.
2. Turn control knob to the (•) position. At this point the
outer tiles will be off and the centre tile and pilot will still
be running.
3. Reach into the back of the heater and turn the cylinder off
by turning the valve hand wheel fully clockwise.
4. Observe the centre tile and pilot to ensure they fully
extinguish.
5. Allow the heater to cool for approximately 30 minutes
before moving or placing in storage.
WARNING:
• Health warning: Do not use if you suffer from
asthma.
Use of this type of heater may worsen existing
breathing conditions.
• This appliance is not intended for unsupervised use by
persons (including children) whose physical, sensory or
mental capabilities; or lack of experience and knowledge
prevents them from using the appliance safely without
supervision or instruction. Children should be supervised
to ensure they do not play with the appliance.
• Use of a fireguard is recommended when used in the
presence of persons who require supervision or who are
unfamiliar with its operation, or in public spaces.
• Use this heater in a ventilated room. Make sure you have
ventilation of at least 105cm
2
. At a minimum there must
be a window opening to outdoors that remains open at
all times while the heater is in operation. The window
must be at least 60cm (600mm) wide and be open at
least 2cm (20mm) during operation of the heater.
• Do not use this heater in bedrooms, bathrooms, toilets,
caravans, or small rooms under 86.4m
3
(cubic metres)
floor area. This is approximately 6m L x 6m W x 2.4m H.
• Keep people, drapes, furniture and other objects at least
1 metre from the heater. Always face the heater towards
the centre of the room.
• Do not place clothes or other objects on the heater. In
addition to the danger from fire, this could affect the safe
and efficient operation of the heater.
• Do not use the heater while people are sleeping.
• Do not move the heater while it is turned on.
Pilot
IMPORTANT:
Do not attempt to re-light until 5 minutes have elapsed.
DO NOT
purge for more than 15 seconds.