SEISMIC RESTRAINT

New Zealand regulations require that flued gas heaters be secured to prevent shifting in the event of an
earthquake. This is best done by fastening the heater to the floor right through the floor protector if one is
fitted. Fasten with two screws not less than 12 gauge or the equivalent in coach screws or toggle fasteners.
Anchor the appliance through the holes in the seismic restraint bracket or in the two angle brackets supplied.
The angle brackets attach at each side of the pedestal. If the seismic restraint bracket is used, it can be
fastened to the rear of the pedestal either before or after fitting the anchor screws. The small centreline hole
in the bracket will help in pre-positioning it.

Angle Bracket

Screw

Centreline Hole

Secure through

these holes

Seismic Restraint Bracket

Spire clip

Screw

TEST FIRING

It is absolutely essential that the installer test fires the heater before leaving the site.

If fitted, open the gas supply valve at the rear of the heater and check all gas joints for leakage using a leak
check solution or an electronic ‘sniffer’, NOT a naked flame.

Test fire the heater, following the lighting instructions on page 6 of this manual.

First check that the pilot light ignites satisfactorily. Initially it may take several attempts until the air is purged
from the pipeline. Once it has lit, extinguish it again and verify instant re-ignition.

Light the main burner to verify satisfactory ignition and cross-lighting. Repeat this procedure several times.
Always wait two or three minutes after turning off the main burner before lighting it again. The main burner
should be test run for at least ten minutes.

After the fire has been alight for five minutes on ‘HIGH’, hold a smoking taper or match at the exit of the
draught hood (behind the heater) to verify that the flue is drawing correctly and that flue gases are not
spilling into the room.

Drawn in: No spillage

Blown out: Spillage/Backdraughting

If satisfactory operation cannot be achieved, contact the Retailer for further advice.

IMPORTANT. It is the responsibility of the installer to instruct the customer on the safe and

correct operation of the appliance, and to ensure that this instruction booklet remains with the

customer.

6

Содержание Estate LP Gas Fire

Страница 1: ......

Страница 2: ... in mobile homes We recommend that you have your heater checked yearly by an Authorised Technician BEFORE INSTALLATION COMMENCES check the data plate on the rear of the heater cabinet to verify that it is the correct type to suit your gas and also that the gas consumption rate is correct for your application CONTENTS OPERATING INSTRUCTIONS 2 Cleaning instructions 2 INSTALLING INSTRUCTIONS 3 6 Heat...

Страница 3: ...l the first time the logs are fired but this will soon disappear After ten minutes set the control to give the desired heat output TURNING THE FIRE OFF Push down and turn the control to the PILOT position The pilot will remain alight To extinguish the pilot light on STD models press down on the control and turn it fully clockwise to the OFF position CLEANING INSTRUCTIONS The outside of the cabinet...

Страница 4: ...INSTALLING INSTRUCTIONS HEATER DIMENSIONS ESTATE AND ULTIMA MODELS 3 ...

Страница 5: ...y from any neighbouring structure The minimum specified clearance distances to heat sensitive materials MUST be maintained at all times and sufficient room will be needed to facilitate servicing the heater Avoid positions where curtains or furniture might accidentally come too close to the heater Select a location where the gas supply can be installed readily INSTALLING PROCEDURE SHIMS On ULTIMA h...

Страница 6: ... of the heater and mark the position on the ceiling Drive a small nail through at this point and inspect the ceiling and roof to ensure that the flue and its trim will be at least 25mm clear of any combustible material The flue termination requirements stated in 3 below will also need to be met 3 Cut appropriate holes through the ceiling and roof material and install the flue in accordance with th...

Страница 7: ...oints for leakage using a leak check solution or an electronic sniffer NOT a naked flame Test fire the heater following the lighting instructions on page 6 of this manual First check that the pilot light ignites satisfactorily Initially it may take several attempts until the air is purged from the pipeline Once it has lit extinguish it again and verify instant re ignition Light the main burner to ...

Страница 8: ...ply at the valve behind the heater Remove the access plate on the rear of the cabinet Disconnect the gas line at the heater Lift the flue trim about 75mm and support it with a wooden block Slacken any flue clamp and lift the flue while moving the heater from beneath it Slide the heater away from the wall supporting the flue and trim on a suitable spacer Keep the heater upright at all times to avoi...

Страница 9: ... it clear Note This will release the top edges of the three glass pieces Ensure that they do not drop out A masking tape strap around the glass at each front corner is useful for this 2 Lift the front glass clear 3 Lift each side glass clear They will reveal at their rear edges a glass sealing rope a backing strip and a spring 4 Assembly is the reverse of the above Clean the inside surfaces of the...

Страница 10: ...e logs out carefully 3 Remove the pedestal rear cover plate 4 Disconnect the feed pipe at the main injector brass elbow 5 Unscrew the main injector 6 Inside the firebox remove the air metering plate just in front of the burner three screws and lift out the draught deflector Remove the four burner retaining screws 7 Ease the burner up a little and remove the entire pilot light igniter assembly two ...

Страница 11: ... spilling from the draught diverter at the rear of the heater Check for flue blockage negative air pressure in the room or circumstances causing down draught Smell of gas in the room Pipe fittings may be leaking Check all joints for leaks including the gas supply system the pilot light supply tube the main burner supply tube and all connections to the control valve and pressure reducing valve NG m...

Страница 12: ...ANNUAL SERVICE RECORD DATE SERVICE DETAILS SERVICED BY KENT Gas Fires are manufactured in New Zealand for GLG NZ LTD P O Box 27 250 Mt Roskill Auckland New Zealand Installed by Date 11 ...

Отзывы: