11
Battery Rejection
If the Fault indicator on the Battery Status Display flashes (see Figure 4) and is
not in condition, the battery is faulty or damaged. If the battery is still within its
warranty period, contact the original manufacturer of the battery pack.
See Troubleshooting table for actions to be taken. If the rejected indicator
continues to flash the battery should be removed and disposed of properly.
Conditioning the Battery
To condition a battery exhibiting a decrease in capacity, insert the battery into
the charger and hold down the "CONDITION" cycle button for two seconds (see
Figure 4). The charger performs a complete (100%) discharge of the battery and
recharges it to full available capacity, eliminating conditions that may cause it to
perform below its rated capacity. This deep discharge cycle may take up to 20
hours to complete.
Note:
This cycle should only be used on NiCD/NiMH batteries and only once
every several weeks. Performing the conditioning cycle on a daily or weekly
basis shortens the usable life of the battery.
If conditioning the battery fails to eliminate the problem, your battery may have
exceeded its usable life and may need replacement. Most batteries have a
usable life of approximately 500 charge/discharge cycles. This number varies
depending on use and battery cell manufacturer.
Troubleshooting
Symptom/Situation Probable Cause Corrective Action/Solution
Power indicator is not lit/
displayed.
Battery Rejected indicator is
displayed. (Yellow flashing)
Charger goes to ready in a
short period of time.
(10-15 minutes)
Charger will not go into
Charge mode. (Yellow solid
indicator)
Charger will not go into
Condition mode.
(Yellow solid indicator)
Battery becomes hot
Power supply shuts
down temporarily
Do not use charger.
Return for repair.
Try another charger.
Remove battery from
charger and reinsert.
Allow to sit in charger for
15 minutes, then reinsert.
Replace battery.
Try conditioning battery.
Replace battery.
Remove battery from charger
and reinsert.
This may take 3-4 cycles to
adequately form new battery
packs.
Replace charger.
Replace battery.
Allow to adjust to ambient
room temperature.
Send in for repair.
Remove battery.
Allow battery to charge
and try condition again.
Send in for repair.
Immediately remove battery
from charger and replace.
Power will automatically
reset.
Bad charger.
Faulty LED.
Faulty condition identified.
Over discharge of battery.
Defective Battery.
Battery is fully charged.
Faulty battery.
New Battery.
Bad charger.
Defective battery.
Battery too cold or hot.
Faulty LED.
Battery too hot.
Battery already discharged.
Faulty LED.
Defective battery.
Power line surge.