18
4-wire receptacle
(NEMA type 14-30R)
Neutral
Neutral
(WHITE wire)
(WHITE wire)
30 AMP
30 AMP
NEMA 14-30
NEMA 14-30
Ground
Ground
(GREEN wire)
(GREEN wire)
Move internal ground (WHITE)
Move internal ground (WHITE)
wire to neutral (SILVER)
wire to neutral (SILVER)
terminal for 4-wire system.
terminal for 4-wire system.
Neutral
Neutral
terminal
terminal
GREEN
GREEN
ground screw
ground screw
BLACK or
BLACK or
RED power wire
RED power wire
BLACK
BLACK
or RED
or RED
power wire
power wire
GREEN
GREEN
ground wire
ground wire
WHITE
WHITE
neutral wire
neutral wire
Electrical connection (non-Canada) - 4 wire cord
Internal ground
Internal ground
(GREEN screw)
(GREEN screw)
Install
Install
UL-approved
UL-approved
strain relief here
strain relief here
Terminal screw
Terminal screw
recovery slot
recovery slot
Line 1
Line 1
(BRASS terminal)
(BRASS terminal)
Neutral
Neutral
(SILVER terminal)
(SILVER terminal)
Line 2
Line 2
(BRASS terminal)
(BRASS terminal)
Access cover
Access cover
screw
screw
Terminal
Terminal
block
block
1
Turn o
ff
power supply to outlet.
2
Remove the screw securing the terminal block access
cover in the lower corner on the back of the dryer.
3
Install a UL-approved strain relief according to the
power cord/strain relief manufacturer’s instructions
in the power cord entry hole below the access panel.
At this time, the strain relief should be loosely in
place.
4
Thread an UNPLUGGED, UL-approved, 30 amp.
power cord, NEMA 14-30 type ST or SRDT, through
the strain relief.
5
Disconnect the dryer internal ground wire (WHITE)
from the ground screw (GREEN) next to the terminal
block.
6
Attach the power cord ground wire (GREEN) to the
ground screw (GREEN) next to the terminal block.
Tighten the screw securely.
7
Move the dryer internal ground wire (WHITE) to the
terminal block and attach it along with the neutral
(WHITE) power cord wire conductor to the center,
SILVER colored terminal on the terminal block.
Tighten the screw securely.
8
Attach the RED and BLACK power cord conductors
to the outer, BRASS colored terminals on the terminal
block. Tighten both screws securely.
9
Follow manufacturer’s guidelines for
fi
rmly securing
the strain relief and power cord.
10
Reinstall the terminal block cover.
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing
could result in personal injury or even death.
WARNING
ELECTRICAL SHOCK HAZARD
Do not make a sharp bend or crimp wiring/conductor at
connections.
NOTE
If a terminal screw falls during cord installation, it can
be retrieved in the terminal screw recovery slot below
the access panel.
Installation Instructions