29
UNBALANCE ERROR
OVER FLOW ERROR
[Note] Environmental check list
1) Removal of transportation-based fixed bolt.
2) Confirmation on the material to see if it is capable
of handling two different types of blanket materials.
Is displayed?
Yes
Does the laundry lean
toward one side, not evenly
put in the DRUM assembly?
Put laundry
evenly
In the DRUM
assembly
Yes
Is the washing machine
installed at an angle?
Adjust the
height of
washing
machine
to be kept
horizontally
Yes
No
Is displayed?
Yes
While a cycle is running,
press the WASH/RINSE and
DELAY START buttons
together to display the water
level. Is the water level
>213?
(Refer to 7-3)
Check the AIR
CHAMBER
and the tube
(clogged).
No
Unplug the washer. Does
the water valve remain on
when the power is removed
from the washer?
Replace the
INLET VALVE ASSEMBLY
If the water
valve is
energized as
soon as the
washer is
plugged in or
when the power
button is
pressed, replace
the main PCB.
No
Yes
Yes