26
8-4. TROUBLESHOOTING WITH ERROR
INLET VALVE ERROR
Is displayed?
When you press both
WASH/RINSE
button and
DELAY START
button
simultaneously,
is the water level < 246?
Is filter inlet valve clogged
with foreign material?
Check the connectors at the
main PCB and the water
valve. Are the connectors
loose or disconnected?
Proceed to next step at right.
Is the resistance of fill valve
coil between 800 and
1200
Ω
?
(Refer to 9-5 inlet valve
assembly.)
Clean or
replace the filter.
Check the AIR
CHAMBER
and the tube
(clogged).
Yes
No
No
Yes
Yes
Reconnect or
repair
the connector.
Replace the
INLET VALVE
ASSEMBLY.
Yes
Yes
Is the voltage at the inlet
valve coil 120VAC with the
valve energized?
Replace the
INLET VALVE
ASSEMBLY.
No
Yes
Yes
Is the wiring correct? Refer to
the wiring diagram for correct
connections.
(Refer to 9-5 wiring diagram)
Replace the
MAIN HARNESS.
No
No
Is the water level still < 246?
Replace the MAIN PWB
ASSEMBLY.
ALWAYS CHECK FOR EXTERNAL CAUSES
Water supply shut off
Frozen water lines
Kinked fill hose
Low water pressure
Check the
pressure
switch. Refer to
test #2.
Yes
No
No
Содержание 796.40019
Страница 2: ...P No MFL30599139 ...
Страница 10: ...9 ...
Страница 12: ...11 5 OPERATION 5 1 CONTROL PANEL FEATURES 4002 9 4027 9 4031 9 ...
Страница 15: ...14 5 2 CYCLE GUIDE 4002 9 ...
Страница 16: ...15 5 2 CYCLE GUIDE 4027 9 ...
Страница 17: ...16 5 2 CYCLE GUIDE 4031 9 ...
Страница 25: ...24 8 3 TROUBLESHOOTING SUMMARY CIRCUIT DIAGRAM ...
Страница 26: ...25 ...
Страница 45: ...44 9 4 PUMP MOTOR ASSEMBLY ...
Страница 46: ...45 9 5 INLET VALVE ASSEMBLY ...
Страница 47: ...46 9 6 HEATER ASSEMBLY ...
Страница 48: ...47 9 7 THERMISTOR ASSEMBLY ...