6-2 PTC / COMBO AND OLP
6
5
Shows continuity
Open
Check another
electric component.
Replace OLP.
Replace PTC-
Starter/Combo
Fig. 44
Fig. 45
Fig. 46
Normal operation of
compressor is impossible
or poor.
?
PTC/ Combo OK
OLP OK
- 17 -
Separate PTC-Starter/
Combo from Compressor
andmeasure resistance
between No.5 and 6 of
PTC-Starter with a tester.
(Fig.44 and Fig.45)
Separate OLP from
compressor and check
resistance value
between two terminals
of OLP with a tester.
(Fig.46)
Observation value is
115V/60Hz: 6.8
Ù
±30%
at room temperature.
The resistance value is
0
Ù (short) or 8 (open).