Kenmore 40289032010 Скачать руководство пользователя страница 6

TROUBLE SHOOTING

A   WARNING

To avoid  risk of electrical shock, personal injury or death; disconnect power to dryer before 
servicing, unless testing requires power.

No Problem

Recommended Checks/Procedures

1

Will Not Start or Run

• 

Check power to the machine.

• 

Dryer is plugged in.

• 

Blown fuse or circuit breaker.

• 

Door switch functional...door closed. Check for error code 3 (See 

Table for codedefinition).

• 

Start/Pause rotary selector dial functional.

• 

Control  Board operational.

• 

Belt off or broken and Belt Cut-off Switch  operates.

• 

Drive motor functional.

• 

Check motor winding resistance: 2.88ohms between pin #3 and 
4 ,3.5ohms between pin #4 and 5.

2

Motor runs/ tumbler

 

will not turn

• 

Belt off or broken/damaged.

• 

Idler tension spring too weak or stretched.

• 

Idler pulley jammed or stuck.

3

Runs a few minutes

 

and then stops

• 

Lint buildup around drive motor.

• 

Low voltage present.

• 

Blower impeller blocked in blower housing.

• 

Drive motor - start switch contacts stuck closed.

4

Blows fuses or trips

 

circuit breaker while

 

running(Elec. Model)

• 

Read a amp.(if machine is drawing high current or if breaker is 

weak, breaker/fuse rated too low, or wrong fuse installed)

• 

Is the belt connected well?

• 

Is the winding of the motor continuous?
(Rotor winding, stator winding, generator)

• 

Is the motor protector normal?

• 

If above points are not found, the PCB assembly is out of order. 
Replace it.

5

Blows fuses or trips

 

circuit breaker while

 

running(Gas Model)

• 

If the dryer is drawing more amperage than it is suppose to, 

then the dryer is at fault.  If the breaker is tripping or fuse is 

blowing and the dryer is drawing the correct amperage, then 
the problem is in the house electrical system.

• 

Igniter harness loose and shorted to base.

• 

Incorrect wiring or wire shorted to ground.

• 

Drive motor winding shorting to ground.

6

Will not heat  (motor

 

runs)

Open heating element.
• 

Regulating thermostat trips easily or is open.

• 

Check Thermistor.

7

Will Not Dry

 

Gas Model

 

Poor Gas Ignition

When the dryer is operated on a heat setting, the igniter should  be 
energized and burner shall fire within 45 seconds at 120 VAC. The 
failure of a component in this system will usually be indicated by one 
of three symptoms:

6

Содержание 40289032010

Страница 1: ...ler cannot be responsible nor assume any liability for injury or damage of any kind arising from the use of this data sheet Due to possibility of personal injury or property damage always contact an authorized technician for servicing or repair of this unit Refer to Service Manual for detailed installation operating testing troubleshooting and disassembly instructions A CAUTION All safety informat...

Страница 2: ... injury or death disconnect power to dryer before servicing unless testing requires power ERROR ITEMS AND DIAGNOSTIC CODES An occurrence of an Error will make a sound of error melody for 5 seconds and continuously show one of the Error Displays from the following errors 2 ...

Страница 3: ...Mode 7 segment will no long display cc and only display the remaining time Service Mode Service Mode This mode is composed to Sensor BarTouch Data Display Mode and Cycle Count Display Mode and Software Version Display Mode Those are Special Test Mode How to Enter 1 Dryer must be on before Service Mode can be entered 2 Press Temp and Chime Keys for 3 seconds or until 3 beeps are heard 3 The machine...

Страница 4: ...mal User Mode Press More Time and Less Time keys simultaneously for 7 seconds 2 This action will put the dryer into Touch Sensor Mode 3 Under Touch Sensor Mode Press More Time Key Converting C F Celsius C 0 00 10 00 20 00 30 00 40 00 50 00 60 00 70 00 Fahrenheit F 32 00 50 00 68 00 86 00 104 00 122 00 140 00 158 00 Celsius C 80 00 90 00 100 00 110 00 120 00 Fahrenheit F 176 00 194 00 212 00 230 00...

Страница 5: ...rouble diagnosis and suitable repair guide Caution for the Repair and Replacement Please follow below instruction for the trouble diagnosis and parts replacement 1 As some electronic components are damaged by the charged static electricity from the resin part of dryer or the human body prepare the human body earth or remove the potential differ ence of the human body and dryer by contacting the po...

Страница 6: ...rcuit breaker while running Elec Model Read a amp if machine is drawing high current or if breaker is weak breaker fuse rated too low or wrong fuse installed Is the belt connected well Is the winding of the motor continuous Rotor winding stator winding generator Is the motor protector normal If above points are not found the PCB assembly is out of order Replace it 5 Blows fuses or trips circuit br...

Страница 7: ... load WeakHi Limit Bad drum seals 11 Improper drying clothes wrinkled Rough texture long dry time Lint filter is not clean Restriction in exhaust Outside exhaust hood damper door stuck closed Exhaust too long too many elbows flex ductwork installed Poor intake air available for the dryer Incorrect tumbler speed Tumbler belt slipping Blower wheel broken check for foreign material in blower area Cus...

Страница 8: ...istance is infinity replace thermostat 3 Thermostat 2resistance 10 Blue Blackwire If resistance is infinity replace thermostat 2 Heater resistance 10 O Blue Blue wire If resistance is infinity replace Heater Measure resistance of the following terminal 1 Door switch open Terminal COM NC 1 3 10 Terminal COM NO 1 2 O 2 Door switch push On Terminal COM NC 1 3 o Terminal COM NO 1 2 1Cl Belt Cut off Sw...

Страница 9: ...s Valve 25M01A Valve 1 2 Resistance value 1 2Kfi Valve 1 3 Resistance value 0 5K fi Valve 4 5 Resistance value 1 2K fi If resistance is infinity replace Valve Thermostat 60T21 Hi Limit 230F 50F Resistance value 1 fi If resistance is infinity replace Thermostat A WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires pow...

Страница 10: ...rt Motor Relay Switch Heater Relay Switch 2 AC Power Off Detection Sensor 3 Door Detection Sensor Sensor Bars temperature sensor check Sensor Bars Disconnect harness and test Pink wire Pin 4 to Orange wire Pin 5 Approx O without laundry This mode is default mode of entering Special Test Mode Refer to page 3 Cycling Thermistor Disconnect harness and test Blue wire Pin 2 to Red wire Pin 6 Approx 10 ...

Страница 11: ...e reconnected to the terminal block support to ground the Dryer frame to the neutral conductor INSTALLATION OF 4 WIRE CORD A External ground connector B Green or bare copper wire of power cord C 1 9 cm UL listed strain relief D Center silver colored terminal block screw E Neutral Grounding wire green yellow F Neutral wire white or center wire Remove the External ground connector screw Connect the ...

Страница 12: ...WIRING DIAGRAM A WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires power WIRING DIAGRAM ...

Отзывы: