TROUBLE SHOOTING

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before 

servicing, unless testing requires power.

INSTALLATION OF 3 PRONG CORD

A.

  External ground connector

B.

  Neutral grounding wire (green/yellow)

C.

  Center silver-colored terminal block screw

D.

  Neutral wire (white or center wire)

E.

  %" (1.9 cm) UL-listed strain relief

1.  Loosen or remove the center terminal block screw.

2.  Connect the neutral wire (white or center wire) of the power cord to the 

center, silver-colored terminal screw of the terminal block. Tighten screw.

3.  Connect the other wires to outer terminal block screws. Tighten screws.
4.  Tighten the strain relief screws.
5.  Insert the tab of the terminal block cover into your Dryer's rear panel slot. 

Secure the cover with a hold-down screw.

W ARNING:

If converting from a 4-wire electrical system to a 3-wire, the ground strap must be reconnected to 

the terminal block support to ground the Dryer frame to the neutral conductor.

INSTALLATION OF 4 WIRE CORD

A. 

External ground connector

B.

  Green or bare copper wire of power cord

C.

  %" (1.9 cm) UL-listed strain relief

D.

  Center silver-colored terminal block screw

E.

  Neutral Grounding wire (green/yellow)

F. 

Neutral wire (white or center wire)

Remove the External ground connector screw.

Connect the ground wire (green or unwrapped) of the power cord to the 
external ground connector screw. If you want to connect B(Green or bare 
copper wire of power cord) to the Neutral Post without assembling with 
A(cabinet ground), call the service technician.
Loosen or remove the center terminal block screw.
Connect the neutral wire (white or center wire) of the power cord and the 
appliance ground wire (green with yellow stripes) under the central screw 
of the terminal block.
Connect the other wires to the outer terminal block screws. Tighten screws. 

Tighten the strain relief screws.

Insert the tab of the terminal block cover into your Dryer's rear panel slot. 
Secure the cover with a  hold-down screw.

Содержание 40289032010

Страница 1: ...ler cannot be responsible nor assume any liability for injury or damage of any kind arising from the use of this data sheet Due to possibility of personal injury or property damage always contact an authorized technician for servicing or repair of this unit Refer to Service Manual for detailed installation operating testing troubleshooting and disassembly instructions A CAUTION All safety informat...

Страница 2: ... injury or death disconnect power to dryer before servicing unless testing requires power ERROR ITEMS AND DIAGNOSTIC CODES An occurrence of an Error will make a sound of error melody for 5 seconds and continuously show one of the Error Displays from the following errors 2 ...

Страница 3: ...Mode 7 segment will no long display cc and only display the remaining time Service Mode Service Mode This mode is composed to Sensor BarTouch Data Display Mode and Cycle Count Display Mode and Software Version Display Mode Those are Special Test Mode How to Enter 1 Dryer must be on before Service Mode can be entered 2 Press Temp and Chime Keys for 3 seconds or until 3 beeps are heard 3 The machine...

Страница 4: ...mal User Mode Press More Time and Less Time keys simultaneously for 7 seconds 2 This action will put the dryer into Touch Sensor Mode 3 Under Touch Sensor Mode Press More Time Key Converting C F Celsius C 0 00 10 00 20 00 30 00 40 00 50 00 60 00 70 00 Fahrenheit F 32 00 50 00 68 00 86 00 104 00 122 00 140 00 158 00 Celsius C 80 00 90 00 100 00 110 00 120 00 Fahrenheit F 176 00 194 00 212 00 230 00...

Страница 5: ...rouble diagnosis and suitable repair guide Caution for the Repair and Replacement Please follow below instruction for the trouble diagnosis and parts replacement 1 As some electronic components are damaged by the charged static electricity from the resin part of dryer or the human body prepare the human body earth or remove the potential differ ence of the human body and dryer by contacting the po...

Страница 6: ...rcuit breaker while running Elec Model Read a amp if machine is drawing high current or if breaker is weak breaker fuse rated too low or wrong fuse installed Is the belt connected well Is the winding of the motor continuous Rotor winding stator winding generator Is the motor protector normal If above points are not found the PCB assembly is out of order Replace it 5 Blows fuses or trips circuit br...

Страница 7: ... load WeakHi Limit Bad drum seals 11 Improper drying clothes wrinkled Rough texture long dry time Lint filter is not clean Restriction in exhaust Outside exhaust hood damper door stuck closed Exhaust too long too many elbows flex ductwork installed Poor intake air available for the dryer Incorrect tumbler speed Tumbler belt slipping Blower wheel broken check for foreign material in blower area Cus...

Страница 8: ...istance is infinity replace thermostat 3 Thermostat 2resistance 10 Blue Blackwire If resistance is infinity replace thermostat 2 Heater resistance 10 O Blue Blue wire If resistance is infinity replace Heater Measure resistance of the following terminal 1 Door switch open Terminal COM NC 1 3 10 Terminal COM NO 1 2 O 2 Door switch push On Terminal COM NC 1 3 o Terminal COM NO 1 2 1Cl Belt Cut off Sw...

Страница 9: ...s Valve 25M01A Valve 1 2 Resistance value 1 2Kfi Valve 1 3 Resistance value 0 5K fi Valve 4 5 Resistance value 1 2K fi If resistance is infinity replace Valve Thermostat 60T21 Hi Limit 230F 50F Resistance value 1 fi If resistance is infinity replace Thermostat A WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires pow...

Страница 10: ...rt Motor Relay Switch Heater Relay Switch 2 AC Power Off Detection Sensor 3 Door Detection Sensor Sensor Bars temperature sensor check Sensor Bars Disconnect harness and test Pink wire Pin 4 to Orange wire Pin 5 Approx O without laundry This mode is default mode of entering Special Test Mode Refer to page 3 Cycling Thermistor Disconnect harness and test Blue wire Pin 2 to Red wire Pin 6 Approx 10 ...

Страница 11: ...e reconnected to the terminal block support to ground the Dryer frame to the neutral conductor INSTALLATION OF 4 WIRE CORD A External ground connector B Green or bare copper wire of power cord C 1 9 cm UL listed strain relief D Center silver colored terminal block screw E Neutral Grounding wire green yellow F Neutral wire white or center wire Remove the External ground connector screw Connect the ...

Страница 12: ...WIRING DIAGRAM A WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires power WIRING DIAGRAM ...

Отзывы: