9
W
arr
anty
Safety
Cleaning
Oper
ation
Installa
tion
Ser
vice P
ar
ts
CONNECT THE WIRING
WIRING DIAGRAM
INSTALL ELECTRICAL WIRING
1. The Downdraft Blower system draws 4 AMPS and requires a 120
VAC, 60 Hz circuit.
2. The unit has a 18 in. long power cord with a 3-pronged plug. Plan
to provide a grounded outlet in a location which will allow the
unit’s power cord to reach.
IMPORTANT - LOCATION OF ELECTRICAL OUTLET:
If Model 59960 is being installed in a 30" wide cabinet...
- or -
If Model 59966 is being installed in a 36" wide cabinet...
...the outlet cannot be located on the back wall of cabinet.
In these cases, the width of the downdraft covers nearly the
entire width of the back wall of the cabinet. So you must
either:
• mount the electrical box to a side wall or cabinet
floor - at least 12 inches from the back wall.
• mount the electrical box to a wall stud behind the
cabinet - where it will not be covered by the downdraft.
Then provide a clearance hole in the back wall of the
cabinet.
3. Mount a standard wiring box, with 3-pronged receptacle, inside
the cabinet. Make sure the downdraft’s power cord can easily
reach it.
4. Run appropriate power cable into cabinet and connect it to
receptacle.
5. Plug the downdraft’s power cord into the outlet.
COMPLETE THE INSTALLATION
WARNING: To avoid possible electrical shock, per-
sonal injury or death - Disconnect electrical power.
INSTALL COOKTOP
1. Align the cooktop with the downdraft and fasten cooktop in place.
NOTE
Accurate alignment of cooktop and downdraft is necessary to ensure
that there is no interference when air vent is raised and lowered.
There should be a gap of 1/32"-1/16" between the back of the cooktop
and the front of the downdraft cover.
ADJUSTMENT
The downdraft is factory-adjusted for proper operation. However,
shipping and handling may affect the position of the activating switch.
To adjust position of activating switch:
1. If downdraft is plugged into electrical outlet, unplug it.
2. Lift air vent straight up and cock it slightly so it remains in the UP
position.
3. Remove switch cover from right end of air vent.
4. Loosen the 2 screws holding the switch bracket in place. Position
switch bracket so that activating switch just comes in contact with
underside of switch membrane. Tighten screws.
5. Replace switch cover, gently lower air vent into chimney, and plug
in power cord. Re-connect electrical power and check operation.
a
Содержание 233.5996 Series
Страница 23: ...23 ...