18
Water heaters covered in this manual have been tested
and approved for installation at elevations up to 2,000 feet
(610 m) above sea level. For installation above 2,000 feet
(610 m), the water heater’s Btu input should be reduced at the
rate of 4 percent for each 1,000 feet (305 m) above sea level
which requires replacement of the burner ori
fi
ce in accordance
with the National Fuel Gas Code ANSI Z223.1/NFPA 54. Contact
your local gas supplier for further information.
Failure to replace the standard ori
fi
ce with the proper high
altitude ori
fi
ce when installed at elevations above 2,000 feet
(610 m) could result in improper and inef
fi
cient operation of the
appliance, producing carbon monoxide gas in excess of the safe
limits. This could result in serious injury or death. Contact your
local gas supplier for any speci
fi
c changes that may be required
in your area.
Use pipe joint compound or Te
fl
on tape marked as being resistant
to the action of petroleum (Propane [L.P.]) gases.
The appliance and its gas connection must be leak tested before
placing the appliance in operation.
The appliance and its individual shutoff valve shall be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 pound per square inch (3.5 kPa). It shall be isolated from
the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 pound per
square inch (3.5 kPa).
Connecting the gas piping to the gas control valve of the water
heater can be accomplished by either of the two methods shown
in Figures 19 and 20.
TEFLON
®
is a registered trademark of E.I. Du Pont De Nemours and Company.
Sediment Traps
Contaminants in the gas lines may cause improper operation
of the gas control valve that may result in
fi
re or explosion.
Before attaching the gas line be sure that all gas pipe is clean
on the inside. To trap any dirt or foreign material in the gas
supply line, a drip leg (sometimes called a sediment trap) must
be incorporated in the piping. The drip leg must be readily
accessible. Install in accordance with the
Gas Piping
section.
Refer to the current edition of the National Fuel Gas Code,
ANSI Z223.1/NFPA 54.
A sediment trap shall be installed as close to the inlet of the water
heater as practical at the time of water heater installation. The
sediment trap shall be either a tee
fi
tting with a capped nipple
in the bottom outlet or other device recognized as an effective
sediment trap. If a tee
fi
tting is used, it shall be installed in
conformance with one of the methods of installation, shown in
Figures 19 and 20.
GAS CONTROL
VALVE / THERMOSTAT
GROUND JOINT
UNION
(OPTIONAL)
3” MIN.
(76.2 mm)
DRIP LEG
(SEDIMENT TRAP)
FIGURE 19. GAS PIPING WITH FLEXIBLE CONNECTOR.
GROUND JOINT
UNION
(OPTIONAL)
3” MIN.
(76.2 mm)
DRIP LEG
(SEDIMENT TRAP)
BLACK PIPE
GAS CONTROL
VALVE / THERMOSTAT
FIGURE 20. GAS PIPING WITH ALL
BLACK IRON PIPE TO GAS CONTROL.