background image

2

3. SAFETY RULES

1.  To reduce the risk of electric shock, insure 

electricity has been turned off at the circuit 

breaker or fuse box before beginning.

2.  All wiring must be in accordance with the 

National  Electrical  Code  and  local 

electrical  codes.  Electrical  installation 

should  be  performed  by  a  qualified 

licensed electrician.

3.  

WARNING:

 To reduce the risk of personal 

injury, use only the two steel screws (and 

lock washers) provided with the outlet box 

for mounting to the outlet box. Most outlet 

boxes  commonly  used  for  the  support  of 

lighting fixtures are not acceptable for fan 

support  and  may  need  to  be  replaced, 

consult a qualified electrician if in doubt.

4.  The outlet box and support structure must 

be  securely  mounted  and  capable  of 

reliably  supporting  a  minimum  of  50 

pounds. Use only CUL Listed outlet boxes 

marked 

"FOR FAN SUPPORT"

.

5.  The fan must be mounted with a minimum 

of 7 feet clearance from the trailing edge of 

the blades to the floor.

6.  Do not operate reversing switch while fan 

blades are in motion. Fan must be turned 

off  and  blades  stopped  before  reversing 

blade  direction.

7.    Avoid  placing  objects  in  the  path  of  the 

blades.

WARNING

TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK OR PERSONAL 

INJURY, MOUNT FAN TO OUTLET BOX 

MARKED "ACCEPTABLE FOR FAN 

SUPPORT".

8.   To avoid personal injury or damage to the 

fan  and  other  items,  be  cautious  when 

working around or cleaning the fan.

  9.  Do  not  use  water  or  detergents  when 

cleaning the fan or fan blades.  A dry dust 

cloth  or  lightly  dampened  cloth  will  be 

suitable for most cleaning.

10.  After  marking  electrical  connections, 

spliced  conductors  should  be  turned 

upward  and  pushed  carefully  up  into 

outlet  box.  The  wires  should  be  spread 

apart  with  the  grounded  conductor  and 

the  equipment  -  grounding  conductor  on 

one side of the outlet box.

11.  Electrical  diagrams  are  reference  only. 

Light kit that are not packed with the fan 

must be CUL Listed and marked suitable 

for  use  with  the  model  fan  you  are 

installing. Switches must be CUL General 

Use  Switches.  Refer  to  the  Instructions 

packaged with the light kits and switches 

for proper assembly.

ATTENTION:

  Canada's  Office  of  Energy 

Efficiency requires this fan to be equipped with 

a 190 watt limiting device. If lamping exceeds 

190 watts, the ceiling fan's light kit will shut off 

automatically.

WARNING

TO REDUCE THE RISK OF PERSONAL 

INJURY, DO NOT BEND THE BLADE 

BRACKETS (ALSO REFERRED TO AS 

FLANGES) DURING ASSEMBLY OR AFTER 

INSTALLATION. DO NOT INSERT OBJECTS 

IN THE PATH OF THE BLADES.

Содержание AC-20152

Страница 1: ...NSTRUCTIONS INSTALLATION INSTRUCTIONS C E T L LISTED MODEL D5201 Weight of Fan 7 92Kgs KENDAL LIGHTING Kendal Lighting BC Inc 110 6780 Dennett Place Delta BC V4G 1N4 Canada Tel 604 952 5510 Fax 604 95...

Страница 2: ...y cover d Coupling cover e Downrod assembly f Fan motor assembly g Mounting plate h Light kit plate i 75W JD type halogen bulbs 2 j Glass shade k Blade set 4 l Blade holder 4 m Receiver 6 wire nuts n...

Страница 3: ...s WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT 8 To avoid personal injury or damage to the fan and other items be caut...

Страница 4: ...weight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade c...

Страница 5: ...ottom of the downrod with the holes in the collar on top of the motor housing Fig 6 Carefully insert the hanger pin through the holes in the collar and downrod Be careful not to jam the pin against th...

Страница 6: ...nuts provided Figure 10 White neutral White neutral Green or bare copper ground White AC IN N White to motor N Ground green Connect to ground wire on hanger bracket if no house ground wire exists Out...

Страница 7: ...12 Step 3 Align the circular hole on canopy with the remaining hole on the hanger bracket secure by tightening the two set screws Note Adjust the canopy screws as necessary until the canopy and canop...

Страница 8: ...NG THE FAN BLADES Figure 13 Figure 14 Screws Screws Mounting plate Mounting ring CAUTION Make sure all screws are tightened securely Step 1 Attach the fan blades to the blade holders by using three sc...

Страница 9: ...with your bare hands Oil residue will shorten the life of the halogen bulb If you accidentally come into contact wipe thoroughly with a clean lint free cotton cloth before installing Allow the bulb t...

Страница 10: ...from the wall outlet box Wire nut the BLACK leads hot together and push back inside the outlet box Fig 19 Step 2 Install the metal plate and wall plate to the existing wall outlet box with 4 screws pr...

Страница 11: ...y has an auto resume it will stay at the same brightness as the last time it was turned off The Reverse switch is located on the top housing Slide the switch to the Left for warm weather operation Sli...

Страница 12: ...appearance over the years Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing Do not use water when cl...

Страница 13: ...ween mounting bracket and outlet box 1 Do not connect the fan with a wall mounted variable speed control s 2 Make sure the dip switches are set correctly 1 This unit may be equipped with a wattage lim...

Отзывы: